Skip to main content
Exxsol D80
Drilling Fluids & Mud Oil Field chemicals
Product code  RXSOL-81-8202-210

Exxsol D80 Fluid is characterized as "de-aromatized" aliphatic hydrocarbon solvent.

Same-day UAE delivery Bulk & custom packaging Technical support included

Product Description

ExxsolD80 Fluid is characterized as "de-aromatized" aliphatic hydrocarbon solvent. The major components are normal paraffins, isoparaffins and cycloparaffins. The product contains very low levels of aromatic hydrocarbons.

EC No.: 926-141-6
Chemical Name: Hydrocarbons, C11-C14, n-alkanes, isoalkanes, cyclics, 2% aromatics
CAS No: 64742-47-8 Chemical Name: Distillates (petroleum), hydrotreated light

Application & Usage

Exxsol D80 Fluid is a liquid solvent used in paints & coatings, consumer products, printing inks, and agricultural chemical applications. It may also be used in food contact applications such as aluminum rolling. It is not sold directly to the public for general consumer uses; however this product may be an ingredient inconsumer and commercial product applications such as metal working solvents and coatings.

Technical Specifications

Exxsol D80 Fluid is a combustible material, has a relatively high vapor pressure, and should be handled only with adequate ventilation and in areas where ignition sources have been removed (e.g. open flames, static electricity sources, unprotected light switches). The flash point is approximately 176ºF /80ºC.

 

Form         Liquid
Colour Colourless
Odour Mild Petroleum/Solvent
Odor Threshold No Information Available
pH Not Applicable
Boiling Point  200°C (392°F) - 250°C (482°F)
Flash Point >=75°C (167°F) [ASTM D-93]
Evaporation Rate (n-butyl acetate = 1): 0.1
Flammability (solid, gas) Not Applicable
Secific Gravity 798 kg/m3
Decomposition Temperature No information available
Solubility in Water Not Soluble
Viscosity No information available

Notes

Environmental Information ::

Exxsol D80 Fluid biodegrades at a rapid rate and will not persist in the environment. It is not expected to cause short-term toxicity to fish or other aquatic organisms. Because of its low solubility in water and volatility (tendency to move from water to air) chronic aquatic toxicity is not expected. This product is expected to degrade rapidly in air. Measures should be taken to prevent its release to the atmosphere and minimize any exposure to the environment from manufacturing or use activities.
 

Handlng ::
 

When using this product, make sure that there is adequate ventilation. Always use chemical resistant gloves to protect your hands and skin and always wear eye protection such as chemical goggles. Do not eat, drink, or smoke where chemicals are handled, processed, or stored. Wash hands and skin following contact. If this product gets into your eyes, rinse eyes thoroughly for at least 15 minutes with tap water and seek medical attention. Please refer to the (Material) Safety Data Sheet.

Material Safety Data Sheet (MSDS)

Product Name Exxsol D80

Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Branch : Kandla, Mumbai, Chennai, Vizag , Kolkata, UAE, OMAN and KENYA

Phone +91 22 2087 1200 - 1400
Fax +91 22 2087 1500 :::AOH :0091 9821214367
Email 123@rxmarine.com
Website www.rxmarine.com

Chemical  Name                                     CAS number GHS Hazard Code  Weight %
DISTILLATES (PETROLEUM), HYDROTREATED LIGHT 64742-47-8  H227, H304       100 %

 

Signal Word Danger
Contains NAPHTHA (PETROLEUM), HYDROTREATED HEAVY

PHYSICAL / CHEMICAL HAZARDS 

readily form flammable mixtures. Vapour accumulation could flash and/or explode if ignited. Combustible.
Material can accumulate static charges which may cause an ignition. Material can release vapours thatreadily form flammable mixtures. Vapour accumulation could flash and/or explode if ignited. Combustible.
HEALTH HAZARDS Repeated exposure may cause skin dryness or cracking. May be irritating to the eyes, nose, throat, and lungs.
Aspiration hazard NA
ENVIRONMENTAL HAZARDS. NA
Hazard Statements Physical: H227: Combustible liquid. Health: H304: May be fatal if swallowed and enters airways.
Precautionary statements - prevention
Prevention: P210: Keep away from flames and hot surfaces. No smoking. P280: Wear protective gloves and
eye / face protection. Response: P301 + P310: IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician. P331: Do NOT induce vomiting. P370 + P378: In case of fire: Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish.

General notes NA
Indication of any immediate medical attention and special treatment needed NA
Skin Contact Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse.
Eye Contact Flush thoroughly with water. If irritation occurs, get medical assistance.
Inhalation Remove from further exposure. For those providing assistance, avoid exposure to yourself or others. Use adequate respiratory protection.If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek Immediate medical assistance. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.
Ingestion Do NOT induce vomiting. Rinse mouth with water (only if the person is conscious)
Most important symptoms/effects both acute and delayed NA
Notes to Physician If ingested, material may be aspirated into the lungs and cause chemical pneumonitis. Treat appropriately.

General information Extinguishing materials should be selected according to the surrounding area. The product itself is not combustible.
Appropriate Extinguishing Media Use water fog, foam, dry chemical or carbon dioxide (CO2) toextinguish flames 
Inappropriate Extinguishing Media:  Straight streams of water
Flammability of the      Product    Flammable.
Suitable extinguishing       media                    Carbon dioxide (CO2), BC-powder, foam, alcohol resistant foam, water mist 
Unsuitable extinguishing    media NA
Hazardous combustion    products  NA
Advice for firefighters  Wear breathing apparatus if exposed to vapours/dust/spray/gases. Co-ordinate firefighting measures to the fire surroundings. Do not allow firefighting water to enter drains or water courses. Collect contaminated firefighting water separately. Fight fire with normal precautions from a reasonable distance. Keep containers cool with water spray. 
Special hazards arising from the substance or mixture  May produce toxic fumes of carbon monoxide if burning. 
Fire Fighting Instructions:  Evacuate area Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA). Use water spray to cool fire exposed surfaces and to protect personnel
Unusual Fire Hazards Combustible.
Hazardous Combustion  Product Incomplete combustion products, Oxides of carbon, Smoke, Fume
Flash Point [Method]: 61 °C (142F) - 66 °C (151F)
Flammable Limits (Approximate volume % in air):  LEL: 0.7 UEL: 5.3
Autoignition Temperature >200 °C (392F)

Notification Procedure 
In the event of a spill or accidental release, notify relevant authorities in accordance with all applicable regulations.
Protective Measur
Avoid contact with spilled material. Warn or evacuate occupants in surrounding and downwind areas if required, due to toxicity or flammability of the material. See Section 5 for fire fighting information. See the Hazard Identification Section for Significant Hazards. See Section 4 for First Aid Advice. See Section 8 for advice on the minimum requirements for personal protective equipment. Additional protective measures may be necessary, depending on the specific circumstances and/or the expert judgment of the emergency responders. For emergency responders: Respiratory protection: half-face or full-face respirator with filter(s) for organic vapor and, when applicable, H2S, or Self Contained Breathing Apparatus (SCBA) can be used depending on the size of spill and potential level of exposure. If the exposure cannot be completely characterized or an oxygen deficient atmosphere is possible or anticipated, SCBA is recommended. Work gloves that areresistant toaromatic hydrocarbons are recommended. Note: gloves made of polyvinyl acetate (PVA) are not water-resistant and are not suitable for emergency use. Chemical goggles are recommended if splashes or contact with eyes is possible. Small spills: normal antistatic work clothes are usually adequate. Large spills: full body suit of chemical resistant, antistatic material is recommended.
 Spillage                  
Land Spill: Stop leak if you can do so without risk. Do not touch or walk through spilled material. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Recover by pumpingor with suitable absorbent. 
Water Spill: Stop leak if you can do so without risk. Warn other shipping. Remove from the surface by
skimming or with suitable absorbents. Seek the advice of a specialist before using dispersants.
Water spill and land spill recommendations are based on the most likely spill scenario for this material; however,
geographic conditions, wind, temperature, (and in the case of a water spill) wave and current direction and
speed may greatly influence the appropriate action to be taken. For this reason, local experts should be
consulted. Note: Local regulations may prescribe or limit action to be taken.
Personal Protection NA
Enviromental Precaution
Large Spills Dike far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas

 

Handling
Avoid contact with skin. Prevent small spills and leakage to avoid slip hazard. Material can accumulate staticcharges which may cause an electrical spark (ignition source). When the material is handled in bulk, anelectrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or earthing procedures. However, bonding and earthing may not eliminate the hazard from static accumulation. Consult local applicable standards for guidance.
Additional references include American Petroleum Institute 2003 (Protection Against Ignitions Arising out of Static, Lightning and Stray Currents) or National Fire Protection Agency 77 (Recommended Practice on Static Electricity) or CENELEC CLC/TR 50404 (Electrostatics - Code of practice for the avoidance of hazards due to static electricity).
Advice on general occupational hygiene Wash hands after use. Do not eat, drink and smoke in work areas. Remove contaminated clothing and protective equipment before entering eating areas. Never keep food or drink in the vicinity of chemicals. Never place chemicals in containers that are normally used for food or drink. Keep away from food, drink and animal feeding
Packaging compatibilities Only packagings which are approved (e.g. acc. to ADR) may be used. Suitable materials and coatings for container/equipment: Carbon Steel, Stainless Steel, Polyester, Polytetrafluoroethylene (PTFE), Polyvinyl Alcohol (PVA) Unsuitable Materials and Coatings for container/equipment: Butyl Rubber, Natural Rubber, Ethylene-propylene-diene monomer (EPDM), Polystyrene, Polyethylene, Polyacrylonetrile
Storage The container choice, for example storage vessel, may effect static accumulation and dissipation. Keep container closed. Handle containers with care. Open slowly in order to control possible pressure release. Store in a cool, well-ventilated area. Storage containers should be grounded and bonded. Fixed storage containers, transfer containers and associated equipment should be grounded and bonded to prevent accumulation of static charge
Transport Temperature  [Ambient]
Transport Pressure  [Ambient]
Loading/Unloading Temperature [Ambient]
STORAGE
The container choice, for example storage vessel, may effect static accumulation and dissipation. Keep container closed. Handle containers with care. Open slowly in order to control possible pressure release.Store in a cool, well-ventilated area. Storage containers should be earthed and bonded. Fixed storage containers, transfer containers and associated equipment should be grounded and bonded to prevent accumulation of static charge.
Suitable Containers/Packing Tank Trucks; Railcars; Barges; Drums
Hygiene measures Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Unsuitable Materials and Coatings
Ethylene-proplyene-diene monomer (EPDM); Natural Rubber; Polystyrene; Butyl Rubber

Exposure Limit Values

Exposure limits/standards (Note Exposure limits are not additive)

Country Chemical Name  Form Limit/Standard Note
 
DISTILLATES (PETROLEUM)  ,
HYDROTREATED LIGHT
Vapor.        
RCP -1200 mg/m3165 ppm       
TWA
Total Hydrocarbon  
Engineerine Controls
The level of protection and types of controls necessary will vary depending upon potential exposure conditions.Control measures to consider: Adequate ventilation should be provided so that exposure limits are not exceeded. Use explosion-proof ventilation equipment.
Personal Protection
Personal protective equipment selections vary based on potential exposure conditions such as applications, handling practices, concentration and ventilation. Information on the selection of protective equipment for use with this material, as provided below, is based upon intended, normal usage
Respiratory Protection
If engineering controls do not maintain airborne contaminant concentrations at a level  which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection,use, and maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to be considered for this material include:Half-face filter respirator Type A filter material.For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded
Hand Protection
Any specific glove information provided is based on published literature and glove manufacturer data. Glove suitability and breakthrough time will differ depending on the specific use conditions. Contact the glove manufacturer for specific advice on glove selection and breakthrough times for your use conditions. Inspect and replace worn or damaged gloves. The types of gloves to be considered for this material include: If prolonged or repeated contact is likely, chemical-resistant gloves are recommended. If contact with forearms is likely, wear gauntlet-style gloves. Nitrile
Eye Protection If contact is likely, safety glasses with side shields are recommended.
Skin and Body Protection
Any specific clothing information provided is based on published literature or manufacturer data. The types of clothing to be considered for this material include: If prolonged or repeated contact is likely, chemical, and oil resistant clothing is recommended
Environmental contols
Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.

                                                                                                    gloves                suit                

                                                                                                      Gloves                       Suit                          

Physical State    Liquid
Form Clear
Colour Colourless
Odour Mild Petroleum/Solvent
Odor Threshold N/D
Relative Density (at 15 °C) N/D
Boiling Point 183 °C (361F) - 208 °C (406F)
Flash Point 61 °C (142F) - 66 °C (151F)
Density (at 15 ºC): 776 kg/m³ (6.48 lbs/gal, 0.78 kg/dm³)
Evaporation Rate 0.7
pH:  N/D
Flammability (Solid, Gas): N/A
Flammable Limits (Approximate volume % in air) LEL: 0.7 UEL: 5.3
Explosive limits

Lower explosion limit (LEL)     -    0.6 vol%

Upper explosion limit (UEL)    -     7 vol%

Vapour pressure 0.269 kPa (2.02 mm Hg) at 20 °C 0.811 kPa (6.1 mm Hg) at 38°C 
Log Pow (n-Octanol/Water Partition Coefficient): N/D
Vapour Density > 1 at 101 kPa
Secific Gravity 0.878
Decomposition Temperature N/D
Solubility in Water:  Negligible
Autoignition Temperature >200 °C (392F)
Solubility in Water Negligible
Kintic viscosit 0.8 – 2 mm²/s at 20 °C
Vapor Pressure: 0.06 kPa at 20 °C
Molecular Weight
0.07 kPa (0.53 mm Hg) at 20 °C 0.24 kPa (1.8 mm Hg) at 38C 0.5 kPa (3.75 mm Hg) at 50 °C
Oxidizing Properties: See Hazards Identification Section. 
Freezing Point:  14°C (7°F) 
Melting Point:  N/D
Hygroscopic: No
Evaporation Rate (n-butyl acetate = 1) 0.05
Log Pow (n-Octanol/Water Partition Coefficient) N/D
Viscosity 1.3 cSt (1.3 mm2/sec) at 40 C 1.64 cSt (1.64 mm2/sec) at 25 °C
Freezing Point -50 °C (-58F)

Reactivity See sub-sections below
Chemical Stability Material is stable under normal conditions
Material to avoid  Strong oxidisers
Incompatible materials Oxidisers
Hazardous Decomposition Products Material does not decompose at ambient temperatures
Hazardous Polymerization Hazardous polymerization will not occur.

Inhalation Acute Toxicity: (Rat) 8 hour(s) LC50 > 5000 mg/m3 (Vapor) Minimally Toxic. Based on test data for structurally similar materials. Test(s) equivalent or similar to OECD Guideline 403  
Iritation No end point data for material
Ingestion Acute Toxicity (Rat): LD50 > 5000 mg/kg Minimally Toxic. Based on test data for structurally similar materials. Test(s) equivalent or similar to OECD Guideline 401
Skin Acute Toxicity (Rabbit): LD50 > 5000 mg/kg Minimally Toxic. Based on test data for structurally similar materials. Test(s) equivalent or similar to OECD Guideline 402
Serious Eye          Damage/Irritation May cause mild, short-lasting discomfort to eyes. Based on test data for structurally similar materials. Test(s) equivalent or similar to OECD Guideline 405
Sensitisation No end point data for material.
Skin Sensitization Not expected to be a skin sensitizer. Based on test data for structurally similar materials. Test(s) equivalent or similar to OECD Guideline 406
Aspiration May be fatal if swallowed and enters airways. Based on physico-chemical properties of the material.
Germ Cell Mutagenicity Not expected to be a germ cell mutagen. Based on test data for structurally similar materials. Test(s) equivalent or similar to OECD Guideline 471 473 474 476 478 479 
Carcinogenicity Data available.
Lactation No end point data for material.
Single Exposure Not expected to cause organ damage from a single exposure.

Ecotoixicity Material -- Not expected to be harmful to aquatic organisms. Material -- Not expected to demonstrate chronic toxicity to aquatic organisms                                                                                                               
mobility
Material -- Highly volatile, will partition rapidly to air. Not expected to partition to sediment and wastewater solids.
Biodegradation Material -- Expected to be inherently biodegradable
Hydrolysis Material -- Transformation due to hydrolysis not expected to be significant
Photolysis  Material -- Transformation due to photolysis not expected to be significant
AtmosphericOxidation Material -- Expected to degrade rapidly in air
VOC Yes

Disposal Recommendation  Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.
Waste treatment method Sewage disposal-relevant information . Do not empty into drains.
Waste treatment of                          containers/packagings Empty containers may contain residue and can be dangerous. Do not attempt to refill or clean containers without proper instructions. Empty drums should be completely drained and safely stored until appropriately reconditioned or disposed. Empty containers should be taken for recycling, recovery, or disposal through suitably qualified or licensed contractor and in accordance with governmental regulations. DO NOT PRESSURISE, CUT, WELD, BRAZE, SOLDER, DRILL, GRIND, OR EXPOSE SUCH CONTAINERS TO HEAT, FLAME, SPARKS, STATIC ELECTRICITY, OR OTHER SOURCES OF IGNITION. THEY MAY EXPLODE AND CAUSE INJURY OR DEATH.
Regulatory disposal      information RCRA Information: The unused product, in our opinion, is not specifically listed by the EPA as a hazardous waste (40 CFR, Part 261D), nor is it formulated to contain materials which are listed as hazardous wastes. It does not exhibit the hazardous characteristics of ignitability, corrositivity or reactivity and is not formulated with contaminants as determined by the Toxicity Characteristic Leaching Procedure (TCLP). However, used product may be regulated.
Remarks Please consider the relevant national or regional provisions. Waste shall be separated into the categories that can be handled separately by the local or national waste management facilities.

Proper Shipping Name PETROLEUM DISTILLATES, N.O.S.
Hazard Class & Division Combustible Liquid
UN / ID Number UN 1268
Packing Group III
ERG Number 128
Label(s) None
Transport Document Name UN1268, PETROLEUM DISTILLATES, N.O.S., COMBUSTIBLE LIQUID, PG III
Land (TDG) Not Regulated for Land Transport
Sea (IMDG) Not Regulated for Sea Transport according to IMDG-Code
Air (IATA) Not Regulated for Air Transport

The hazard classification for this material is in accordance with the General Rules for Classification and Hazard Communication of Chemicals (GB 13690-2009).
Osha Hazard Communication Standard This material is considered hazardous in accordance with OSHA HazCom 2012, 29 CFR 1910.1200.
Listed or exempt from listing/notification on the following chemical inventories AICS, DSL, ENCS, KECI, PICCS, TSCA 
Cercla
This material is not subject to any special reporting under the requirements of the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA). CERCLA petroleum exclusion applies for this product. Contact local authorities to determine if other reporting requirements apply. 
CWA / OPA This product is classified as an oil under Section 311 of the Clean Water Act (40 CFR 110) and the Oil Pollution Act of 1990. Discharge or spills which produce a visible sheen on either surface water, or in waterways/sewers which lead to surface water, must be reported to the National Response Center at 800-424-8802. 
Sara (313) Toxic Relese Inventory This material contains no chemicals subject to the supplier notification requirements of the SARA 313 Toxic Release Program.

Other Information

The information above is believed to be accurate and represents the  best information   currently    available  to us.  However,   we   make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and  weassume  no liability resulting from its use. Users should make  their  own  investigations  to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International  has been advised of the possibility of such damages.

Supply Locations

Exxsol D80 manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Exxsol D80 at a competitive price from us. We have ready stock of Exxsol D80 in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Need pricing or a bulk quote?

Send us the product and quantity — our team replies with a quote same day.

WhatsApp Us