Of Marine Chemical Solutions
Of Marine Chemical Solutions
Potable Water Stabiliser effectively and economically provides scale and corrosion control in potable water systems and other shipboard once-through water systems.
25.00Kg.(PWD)
Potable Water Stabiliser effectively and economically provides scale and corrosion control in potable water systems and other shipboard once-through water systems.
Odour | Odourless |
Appearance | powder, white, soluble in water |
Contact with eyes | Prolonged exposure may cause abrasive irritation of the eyes |
Contact with skin | In cases of severe exposure, irritation may develop |
Inhalation | Prolonged exposure may cause abrasive irritation of the mucous membranes |
Ingestion | The ingestion of significant quantities may cause gastro-intestinal disturbances |
Product Technical bulletin
Potable Water Stabiliser effectively and economically provides scale and corrosion control in potable water systems and other shipboard once-through water systems.
Dosage varies between 4 – 8 mg/ltr for ordinary water treatment. For drinking water, dosage should always be kept at or below 9 mg/ltr (9 g/ton).
The powder product should not be dosed directly into the water system. A water solution should be made prior to dosing.
Potable Water Stabiliser should be dosed to a suitable point in the system. If the expansion tank is used, adequate circulation must be assured.
Make a 5% solution in fresh water by adding the powder slowly to the water while stirring. The solution should preferably ne portioned to maintain desired dosage, either by means of a simple bypass feeder.
The product can be injected into the discharge line of the fresh water generator or directly into the fresh water pumps’ suction manifold. If a high percentage of shore water is used the solution must be “slug” dosed into the tanks prior to taking water.
Inject a 5% solution at a rate of 0.12 litres per m3 of water to obtain a 6 mg/ltr concentration.
Example
For 20 m3 per day: Dose 0.1 ltr/hour = 2.4 ltr/day of the solution.
For 100 m3 per day: Dose 0.5 ltr/hour = 12 ltr/day of the solution.
For larger systems, stronger solutions up to 20% can be made. The dosage rate may then be reduced proportionally, which will extend the time period between each filling of the dosing tank. However, production of stronger solutions may require improved stirring equipment.
Prevents «Red Water» in potable water systems. Provides scale and corrosion control in hot water heaters, coolers and water tanks. Controls corrosion in pipelines and other equipment handling softened or evaporated water. Effective at temperatures up to 60°C (140°F). Increases system life and reduces maintenance costs. A
Weight |
25 kg |
Density |
1.2 |
Packing, Type |
Plastic |
pH |
9 |
Colour |
WHITE |
Appearance |
POWDER |
Product label