ORG MC 511 (Membrane Cleaner) is a high pH liquid formulation designed to remove organics, silt, and other particulate deposits from polysulfone, fluorocarbon, and all polyamide thin film composite reverse osmosis (RO) and ultrafiltration (UF) membranes. The product is effectively used in nanofiltration (NF), and microfiltration (MF) application. This product provides superior cleanings allowing longer run times.
Applications :
During the operation of a membrane separation system, organic materials as well as suspended solids in the incoming water can accumulate on the membrane surface. The presence of organic materials also provides an environment conducive to microbiological activity, which can result in microbiological fouling. Fouling from these species impedes the flow of water through the membrane. This can result in unacceptably low production, high operating pressure, or an excessive pressure drop in the system, which may lead to irreversible membrane damage. Additionally, accumulation of these foulants on the membrane surface can increase the amount of dissolved material passing through the membrane, resulting in product water of unacceptable quality. Before these foulants can accumulate to a level where product water declines or membrane damage can occur, they should be removed by a clean-in-place (CIP) off-line cleaning. Indications of the need for cleaning include a significant decrease in normalized permeate flow, a significant increase in pressure drop across the system (or individual stage), or an increase in the normalized salt passage, such that product quality is unacceptable. Rx Marine International representative can assist you with monitoring your system and determining when cleaning is advised.
ORG MC 511 (Membrane Cleaner) contains a blend of solubilizing and complexing agents designed to specifically remove organic and particulate foulants from the surfaces of the membrane. Used in tandem with an acidic cleaner for scale removal, regular cleanings with ORG MC 511 (Membrane Cleaner) can help to preserve the life of your membranes.
Depending on the nature of the fouling, a soak period may be necessary for optimum results. Consult Rx Marine International representative for details.
ORG MC 511 (Membrane Cleaner) is not a biocide. If sterilization of the membrane and equipment surfaces is desired, contact Rx Marine International representative.
Feed Requirements
Feed System – This product should be used in conjunction with the membrane cleaning equipment supplied by the manufacturer of the membrane system. If such a system is not present, contact Rx Marine International representative for information on fabricating or obtaining a cleaning system.
Dose :
Dilution – The product must be diluted prior to introduction into the membrane system. The recommended dilution for this product is 500 Grams of ORG MC 511 (Membrane Cleaner) per 20 Ltrs of water.
General Cleaning Instructions
The following general cleaning procedure can be followed. For the optimum cleaning procedure for your system, contact
Rx Marine Internation Representative.
Physical and Chemical Properties :
Appearance |
Colorless To Amber |
Physical State |
Liquid |
Specific Grav.(70F,21C) |
1.197 |
pH As Is (approx.) |
10.9 |
Odor |
Slight |
Flash Point P-M |
(CC) > 200F > 93C |
Vapor Pressure (mmHG) |
~ 18.0 |
Freeze Point (F) |
23 |
Vapor Density (air=1) |
~ 5.00 |
Freeze Point (C) |
-5 |
Viscosity(cps 70F,21C) |
99 % |
Solubility (water) |
100.0 |
Evaporation Rate |
(Ether=1) < 1.00 |
Materials Compatibility –
Corrosion-resistant equipment, such as PVC, should be used for the storage and preparation of this product. Pumping materials coming in contact with the concentrated or diluted products should also be corrosion resistant.
Packaging Information:
ORG MC 511 (Membrane Cleaner) is a liquid material, available in a wide variety of customized containers and delivery methods. Contact your GE representative for details.
Safety Precautions
A Material Safety Data Sheet containing detailed information about this product is available upon request.
Product label
Compatible with polyamide thin-film composite membranes
Optimum results are obtained when used in conjunction with ORG MC 882
Extremely effective against oils and many other organic compounds
Excellent results when used to clean biological matter and eliminate biological slime from the membrane surface
Buffered to maintain an effective pH over a range of dilutions
Enhanced performance at elevated temperatures
Liquid cleaner which allows shorter mixing time.
Low foam formulation
No adverse effects with repeated use
ORG MC 511 (Membrane Cleaner) is a high pH liquid formulation designed to remove organics, silt, and other particulate deposits from polysulfone, fluorocarbon, and all polyamide thin film composite reverse osmosis (RO) and ultrafiltration (UF) membranes. The product is effectively used in nanofiltration (NF), and microfiltration (MF) application. This product provides superior cleanings allowing longer run times.