• Sharjah Chemical, Sharjah
  • Leading Provider

    Of Marine Chemical Solutions

  • Leading Provider

    Of Marine Chemical Solutions

Product Details

Home Product Details

Request For Quote





Product Search

Corrosion Inhibitor Nitrite – Phosphonate for CLOSED LOOP

Closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets.
25.00Ltr.

Product Enquiry
SKU: RXSOL-40-4013-020 Category:

Product Description

It is a high performance nitrite based closed circuit inhibitor with phosphonate with unique formulation with ferrous & Non ferrous corrosion inhibitors, antiscalants , dispersant and buffer solution of non carbonate.
Usefull for use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.

 

Product Technical bulletin

COOLING WATER TREAT. CORROSION INHIBITOR
Corrosion Inhibitor Nitrite – Phosphonate for CLOSED LOOP
(High Nitrite Contentite )   RXSOL-40-4013-020        
Liquid(For Radiators, DG-sets, Closed Cooling System)

Introduction: RXSOL-40-4013-020 is a high performance nitrite based closed circuit inhibitor with phosphonate.unique formulation with organic Corrosion Inhibitors,Anti-Scalant for use in closed cooling water systems,for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system,DG set at high or low temperature.It is a concentrated liquid ,also used as a corrosion inhibitor ( Protects all the metals including cast iron,mild steel,copper .

Note: The stable oxide film that is formed by RXSOL-40-4013-020 prevents corrosion caused by electrolytic action between dis -similar metals used in the system.RXSOL-40-4013 has been field tested and found to have no detrimental effects on non metallic substances such as seals, glands,packing,hoses, gaskets etc., normally used in these’systems.

Applications-Dg*Sets :Internal combustionengines closed circuit cooling system compressor cooling system.RXSOL-40-4013-020 incorporates superior corrosion inhibitors to prevent corrosion works by free of scale deposits.

Advantages: Prolong the life of equipment by keeping scale and corrosion free. Since RXSOL-40-4013-020 is alkaline and so will suppress acid corrosion, which would otherwise result in corrosion damage such as pitting. However, the alkalinity control  is such that even if the product is accidentally overdosed, the pH of the water will remain within limits. The  metals which would be affected by extremes of alkalinity or acidity are protected

. Improves generating cooling efficiency by maintaining a clean heat transfer
. Reduced maintenance and down   time
. Compatible with Coolants / Antifreeze solution / Glycol .
. Friendly with   Metals (Like steel, Copper, Aluminum, all alloys) & Non-metal (Rubber, Hoses, Gasket etc.)

Note: In cases where systems are contaminated with oil and/or scale they should be cleaned before starting to apply RXSOL-40-4013-020.There are suitable RX BRAND products to carry out the cleaning. Degreasing should be carried out using RXSOL-10-1005-OB and descaling by using RXSOL-11-1008-DC

Specification :

Color Clear/Pink (Colour changes of the product can not beexcluded the  effectively will however not  impaired.)Sp.Gravity
pH 1.1 to 1.25  
Odour (9)None.  
Freezing  Point         17 0
Nitrite (as PPM NO2) 0 100-200 300-600    700 -900 1100-1300 1440-2400
RXRXSOL-40-4013 / 1000L 13.0 11.3 8-10 5-7 1.5-3.5 0

 

Handling: RXSOL-40-4013-020 is an alkaline product &should be handled like other chemical Avoid contact with Eyes,Skin,in case of contact,wash with copious amounts of water  immediately

Method Of  Use:
1.Properly   clean  the  system  with  water  and  alkaline  liquid ,  if  necessary.
2.Add  0 .15-1.5 % of RXSOL-40-4013-020 in system or recommended Nitrite level 1400 – 2500 ppm can be measured and controlled  by  any standard  RXSOL test  kit  for  Nitrite,Chloride  test  also helps  to detect excess contamination  to  maintain  accepted  levels.
3.when the product is dosed as recommended  limit By buffering action of RXSOL-40-4013-020 ,pH should be maintained between 8.3 and 10 by the treatment.

Note: Initial dosage for an untreated system is 9 litres of RXSOL-40-4013-020 /1000 litres of untreated distilled water.This will bring the treatment up to the minimum level of 1000 ppm nitrite.For best  result and  prolonged  engine life add  RXSOL-40-4013-020  every  500 -6500  km. or  250  to  300 hours  of  running  time  or  every  2 month   interval.

         

Product label
RXSOL-40-4013-020 is a unique formulation with organic Corrosion Inhibitors,Anti-Scalant for use in closed cooling water systems,for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system,DG set at high or low temperature.It is a concentrated liquid ,also used as a corrosion inhibitor ( Protects all the metals including cast iron,mild steel,copper .

X

Request for Quote and Get Heavy Discount on Price