Corrosion Inhibitor for Diesel Cooling Water Treat

Anti-Scalant for use in closed cooling water systems , for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is a concentrated liquid , also used as a corrosion inhib
25.00Ltr.

Product Enquiry
SKU: RXSOL-40-4033-025 Category:

Product Description

Corrosion Inhibitor for Diesel Cooling Water Treatment – RXSOL CIDC is a unique formulation with organic Corrosion Inhibitors, Anti-Scalant for use in closed cooling water systems, for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is a concentrated liquid, also used as a corrosion inhibitor ( Protects all the metals including cast iron, mild steel, copper .)

Product Technical bulletin

Introduction

RXSOL CIDC is a unique formulation with organic Corrosion Inhibitors , Anti-Scalant for use in closed cooling water systems , for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is a concentrated liquid , also used as a corrosion inhibitor ( Protects all the metals including cast iron , mild steel , copper .

Note :

The stable oxide film that is formed by RXSOL CIDC prevents corrosion caused by electrolytic action between dissimilar metals used in the system .RXSOL CIDC has been field tested and found to have no detrimental effects on non metallic substances such as seals, glands, packing, hoses, gaskets etc., normally used in these’ systems.

Application-Dg*

Sets Internal combustion engines closed circuit cooling system compressor cooling system. RXSOL CIDC incorporates superior corrosion inhibitors to prevent corrosion works by free of scale deposits.

Advatages: –

1. Prolong the life of equipment by keeping scale and corrosion free. Since RXSOL CIDC is alkaline and so will suppress acid corrosion, which would otherwise result in corrosion damage such as pitting. However, the alkalinity control is such that even if the product accidentally overdoses, the pH of the water will remain within limits. The metals which would be affected by extremes of alkalinity or acidity are protected.

2. Improves generating cooling efficiency by maintaining a clean heat transfer

3. Corrosion protection by using superior corrosion inhibitor.

4. Reduced maintenance and down time

5. Compatible with Coolants / Antifreeze solution / Glycol .

6. Friendly with Metals (Like steel, Copper, Aluminum, all alloys) & Non-metal (Rubber, Hoses, Gasket etc.)

Note:

In cases where systems are contaminated with oil and/or scale they should be cleaned before starting to apply RXSOL CIDC. There are suitable RX BRAND products to carry out the cleaning. Degreasing should be carried out using RXSOL SC 2002 and descaling by using RXSOL DC 1008 .

SPECIFICATION / HANDLING
Color  : Pink/ red (Colour changes of the product can not be excluded the effectively will however not impaired.)
Sp. Gravity : 1.1 to 1.25
pH    Alkaline (11.3 – 11.5)
Odour None.

RXSOL CIDC is an alkaline product & should be handled like other chemical Avoid contact with Eyes, Skin ,in case of contact ,wash with copious amounts of water immediately.

Freezing Point – 17 0 c Nitrite (as PPM NO2) 0 100-200 300-600 700-900 1100-1300 1440-2400 RXSOL 2000 /1000L 13.0 11.3 8-10 5-7 1.5-3.5 0

METHOD OF USE
1. Properly clean the system with water and alkaline liquid, if necessary.
2. Add 0 .15-1.5 % of RXSOL CIDC in system or recommended Nitrite level 1400 – 2500 ppm can be measured and controlled by any standard RXSOL test kit for Nitrite, Chloride test also helps to detect excess contamination to maintain acceptable levels. when the product is dosed as recommended limit By buffering action of RXSOL CIDC, pH should be maintained between 8.3 and 10 by the treatment.

NOTE : Initial dosage for an untreated system is 9 litres of RXSOL CIDC / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine, life add RXSOL CIDC every 500 -6500 km. or 250 to 300 hours of running time or every 2-month interval.

Product label
RXSOL CIDC is a unique formulation with organic Corrosion Inhibitors, Anti-Scalant for use in closed cooling water systems, for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is a concentrated liquid, also used as a corrosion inhibitor ( Protects all the metals including cast iron, mild steel, copper