Of Marine Chemical Solutions
Of Marine Chemical Solutions
It is a corrosion inhibitor is a catalyzed liquid catatonic, filming amine corrosion inhibitor and oxygen scavenger , This formulation is especially effective way of protecting ferrous and aluminum metals from corrosion due to adverse environmental cond
20.00Ltr.
Oxygen Control Corroision Inhibitor
RXSOL-50-5007-020 corrosion inhibitor is a catalyzed liquid catatonic, filming amine corrosion inhibitor and oxygen scavenger , This formulation is especially effective way of protecting ferrous and aluminum metals from corrosion due to adverse environmental conditions such as high heat and humidity, seawater or other harsh environments , for boiler and steam line corrosion protection. As an additional benefit it will assist to neutralize dissolved cabon dioxide. It provides the required condition for the estabishment of a pasivity layer (magnetite) in the boiler and condensate system.
will control corrosion from salt water due to CO2, inorganic salts, dissolved oxygen and H2S contamination from sour fluids or bacterial action.
Product Technical bulletin
Oxygen Control Corroision Inhibitor
RXSOL-50-5007-020
Introduction:-
RXSOL-50-5007-020 corrosion inhibitor is a catalyzed liquid oxygen scavenger , This formulation is especially effective way of protecting ferrous and aluminum metals from corrosion due to adverse environmental conditions such as high heat and humidity, seawater or other harsh environments , for boiler and steam line corrosion protection. As an additional benefit it will assist to neutralize dissolved cabon dioxide. It provides the required condition for the estabishment of a pasivity layer (magnetite) in the boiler and condensate system.
DOSE:-
RXSOL-50-5007-020 The objective is to maintain a hydrazine residual between 0.05-0.2 ppm depending on operating pressure and boiler designe. Actual consumption is determined under operating conditions. A normal dosage is approximately 1 ltr. per day, depending of system layout.
Powder Application:-
For average conditions the recommended dosage is 0.30 ounces (weight) per cubic foot (28 Liters) of enclosed space.( 300 g/cubic meter) Concentration can be increased to protect metals under more severe conditions. Powder is applied by air fogging or sprinkle and then the treated area is closed or sealed.
Liquid Application:-
For average conditions the recommended dosage as a solution is a 0.25% in water (based upon weight). This solution is recommended as a hydrostatic test fluid or as an additive to a final rinse in metalworking applications. Concentration can be increased to protect metals under more severe conditions. The treated area is then closed or sealed.
Products Properties:-
Non-Flammable
Safe Plant Handling
Low Odor
Provides corrosion protection in the liquid and the vapor phase
When used in hydrostatic testing the product provides protection in liquids below, above and at the liquid levels
Protection of recessed and hard to reach areas. Complicated valves and the interior surfaces of piping and equipment, which are often difficult or impossible to reach, are protected with true Vapor Corrosion Inhibitor action Easy to Useits POWDER can be applied by either blowing with conventional air blasting equipment or other methods using compressed air . Can be applied by sprinkling , rinsing or dipping metals in a solution of RXSOL-50-5007-020 , hydrotest solution, metalworking fluids, coatings, adhesives and water treatment formulations.
PACKAGING : 25 ltrs. / 210 Ltrs.
ACTIVE MATTER : 78-83%
COMMON NAME : Oxygen control corroision inhibito for FEROUS & ALUMINUM
Product label
RXSOL-50-5007-020 corrosion inhibitor is a catalyzed liquid catatonic, filming amine corrosion inhibitor and oxygen scavenger , This formulation is especially effective way of protecting ferrous and aluminum metals from corrosion due to adverse environmental conditions such as high heat and humidity, seawater or other harsh environments , for boiler and steam line corrosion protection. As an additional benefit it will assist to neutralize dissolved cabon dioxide. It provides the required condition for the establishment of a passivity layer (magnetite) in the boiler and condensate system.
Request for Quote and Get Heavy Discount on Price