LIME Marine Water Scale Remover
RXSOL-16-1747-025LIME Marine is a safe, biodegradable marine descaler developed to dissolve problematic fouling mediums including calcium, rust, mussels, barnacles, tiger shells and other scale formed mineral deposits that hinder the performance of vital water system
Product Description
RXSOL MARINE WATER SCALE REMOVER
Product Code: RXSOL-25-1747-025
Specialized Descaling Chemical for Marine Water Systems, Seawater Pipelines, Heat Exchangers and Industrial Equipment
RXSOL Marine Water Scale Remover is a specialized chemical cleaning product designed to remove mineral scale, calcium carbonate deposits, magnesium-based deposits, salt-related encrustations and other inorganic fouling from compatible marine water systems and industrial equipment.
Marine water systems frequently experience scaling due to the presence of dissolved calcium, magnesium and other mineral salts in seawater and freshwater. Over time, these deposits accumulate on internal surfaces, reducing water flow, restricting heat transfer and affecting equipment performance.
RXSOL Marine Water Scale Remover is intended to dissolve and loosen stubborn mineral deposits, helping restore system cleanliness, improve water circulation and support efficient operation.
The product is suitable for controlled chemical descaling of compatible seawater cooling systems, heat exchangers, marine pipelines, pumps, condensers and associated water-handling equipment.
LIME Marine is a safe, biodegradable marine descaler developed to dissolve problematic fouling mediums including calcium, rust, mussels, barnacles, tiger shells and other scale formed mineral deposits that hinder the performance of vital water systems. RXLYME Marine is formulated to meet the demands of today's water systems. LIME Marine is non-corrosive, non-hazardous, and biodegradable . With the reduction of labour and operating costs, downtime, and no installation costs, accompanied with the heavy duty cleaning power, LIME Marine keeps your vessel at sea generating revenue.
Application & Usage
Key Features & Benefits
-
Effective removal of calcium carbonate and common mineral scale deposits.
-
Helps dissolve hard water scale and seawater-related encrustations.
-
Suitable for marine and industrial water system maintenance.
-
Helps restore water flow through scaled pipelines and equipment.
-
Improves heat-transfer performance where mineral deposits cause fouling.
-
Reduces the need for extensive mechanical descaling.
-
Suitable for controlled circulation and immersion cleaning.
-
Useful for preventive and corrective maintenance programmes.
-
Can assist in cleaning difficult-to-access internal passages.
-
Supports maintenance of marine cooling and water circulation systems.
Major Applications
Marine Seawater Cooling Systems
Used for removing mineral deposits from compatible seawater cooling circuits, pipelines and cooling equipment.
Heat Exchangers
Helps dissolve scale deposits on compatible heat-transfer surfaces, improving thermal performance where fouling has reduced efficiency.
Marine Condensers
Suitable for controlled descaling of compatible condenser tubes and associated water passages.
Seawater Pipelines
Assists in removing mineral encrustations and scale deposits that restrict internal flow.
Pumps and Valves
Can be used to clean compatible dismantled components affected by hard water scale and mineral accumulation.
Freshwater Generators and Evaporators
Suitable for selected descaling applications, subject to equipment manufacturer recommendations and material compatibility.
Industrial Water Systems
Used in compatible cooling circuits, process water pipelines and industrial equipment affected by mineral scale.
Safety & Handling
-
Read the latest product Safety Data Sheet before use.
-
Wear suitable chemical-resistant gloves, goggles and protective clothing.
-
Avoid skin and eye contact.
-
Provide adequate ventilation.
-
Do not mix with chlorine-containing chemicals, hypochlorite or other cleaning agents.
-
Use compatible pumps, hoses, tanks and dosing equipment.
-
Monitor the cleaning process to avoid excessive metal exposure.
-
Collect and dispose of spent cleaning solutions in accordance with applicable regulations.
If the product contains acid, additional precautions may be required for corrosivity, hydrogen generation with reactive metals and carbon dioxide release during carbonate scale dissolution.
Storage
Store in the original tightly closed container in a cool, dry, well-ventilated area.
Protect from direct sunlight, excessive heat and incompatible chemicals.
Keep containers properly labelled and use suitable secondary containment.
Packing
Product Name: Marine Water Scale Remover Product Code: RXSOL-25-1747-025 Packing Size: 25 Litres
Other bulk packing arrangements may be considered subject to availability.
This safe and simple solution effectively dissolves rock-like scale deposits that contaminate your water-cooled marine equipment. LIME Marine is used at ambient temperature and then circulated to bring the solution in contact with the accumulated minerals. The reaction results in a slight foaming or bubbling action, indicating the deposits are actually dissolving into solution, and then simply water flush away! These scale deposits, along with zebra mussels and tiger shells, damage your equipment and reduce your water system performance. Historically, these problems have been addressed via harsh acids, mechanical methods, ion exchange, polyphosphates, permanent magnets and electronic conditioning. If your vessel is heat exchanger cooled, keel cooled, or radiator cooled, try LIME Marine and ride the waves with maintenance superiority.
Dosage
Directions for Use
A. Circulation Cleaning Method
Recommended for compatible heat exchangers, seawater pipelines, condensers and closed water circuits.
-
Shut down and isolate the equipment to be cleaned.
-
Drain the system and remove loose debris where practical.
-
Inspect the system materials and confirm chemical compatibility.
-
Prepare the descaling solution at the concentration specified in the product TDS.
-
Circulate the solution through the scaled system using a suitable chemical-resistant pump.
-
Monitor scale dissolution, solution condition and relevant process parameters.
-
Continue circulation until the required cleaning endpoint is achieved.
-
Drain and collect the spent cleaning solution.
-
Rinse thoroughly with clean water until the required post-cleaning conditions are achieved.
-
Neutralize or passivate the system where required by the equipment maintenance procedure.
Important: If the formulation is acid-based, monitor gas evolution and avoid operating the cleaning circuit as a sealed, unvented system.
B. Immersion Cleaning Method
Suitable for compatible dismantled components.
-
Place the components in a chemically resistant cleaning tank.
-
Prepare the descaling solution according to the approved TDS.
-
Immerse the components in the solution.
-
Allow sufficient contact time for scale dissolution.
-
Inspect periodically and remove loosened deposits where necessary.
-
Remove the components and rinse thoroughly with clean water.
-
Dry and protect the cleaned components as required.
C. Manual Cleaning Method
For accessible compatible surfaces, apply the product using an approved chemical-resistant applicator.
Allow controlled contact with the scale deposit, then rinse thoroughly. Avoid allowing concentrated chemical to remain on sensitive surfaces.
LIME Marine should be used as directed and at any temperature within the operating limits between 0°F / -18°C and 180°F / 82°C. If the solution does freeze, slush or thicken at the lower operating temperatures, and then thaws, there will be no performance reducing results. Please consult the manufacturer when temperatures above 180°F are encountered.
RXLYME Marine should be applied at ambient temperatures with no heating required. The solution is exothermic, but does not develop a substantial increase in temperature while dissolving water scale, rust, mussels, barnacles, zebra mussels, tiger shells and other water formed deposits.
Useful Area
Technical Recommendation
For the most effective descaling programme, identify the deposit composition and equipment metallurgy before selecting the chemical concentration and cleaning procedure.
A complete marine water system cleaning programme may include preliminary flushing, chemical descaling, thorough rinsing, inspection and suitable post-cleaning corrosion protection.
RXSOL CHEMO PHARMA INTERNATIONAL
Product: Marine Water Scale Remover Product Code: RXSOL-25-1747-025 Category: Marine Maintenance Chemicals / Descaling Chemicals
Website: www.rxmarine.com
Industrial Area
Frequently Asked Questions
Q1. What is RXSOL Marine Water Scale Remover used for?
It is intended for removing mineral scale and seawater-related deposits from compatible marine cooling systems, pipelines, heat exchangers and industrial water equipment.
Q2. Can it remove calcium carbonate scale?
Yes, calcium carbonate is a principal target for suitable chemical descaling formulations.
Q3. Can Marine Water Scale Remover be used in seawater heat exchangers?
It may be suitable, provided the chemical formulation is compatible with the heat exchanger tubes, gaskets and other wetted materials.
Q4. Is the product safe for copper-nickel and aluminium brass tubes?
Compatibility cannot be guaranteed without knowing the exact descaling chemistry and corrosion-inhibitor package. These alloys require specific evaluation.
Q5. Can the product be circulated through pipelines?
Yes, controlled circulation is a common descaling method, provided the system is compatible and the cleaning procedure follows the approved TDS.
Q6. Does the product remove rust and oil deposits?
Its primary purpose is mineral scale removal. Rust, heavy oil, biological fouling and silica-rich deposits may require separate or additional cleaning treatments.
#LIME_Marine_Scale_Remover
#LimeScale_remover
Technical Specifications
Typical Physical & Chemical Properties
|
Property |
Typical Description |
|---|---|
|
Product Name |
Marine Water Scale Remover |
|
Product Code |
RXSOL-25-1747-025 |
|
Product Type |
Chemical Descaling Agent |
|
Appearance |
Liquid, subject to supplied formulation |
|
Chemical Nature |
Descaling formulation; chemistry to be confirmed |
|
Primary Function |
Removal of inorganic mineral scale |
|
Target Deposits |
Calcium carbonate, magnesium-based scale and mineral encrustations |
|
Application |
Circulation / Immersion / Controlled Manual Cleaning |
|
Water Dilution |
As specified in the approved TDS |
|
Packing |
25 L |
The exact chemical composition, pH, specific gravity, flash point and corrosion-inhibitor system have not been provided. These properties must be confirmed from the finished product formulation and quality-control results.
Technical Disclaimer: This bulletin provides general application guidance. Product-specific dosing, chemical composition, performance specifications and material compatibility must be established using the approved formulation, laboratory test results and equipment requirements before operational use.
|
PHYSICAL STATE |
: LIQUID, DARK LIQUID |
| BOILING POINT |
: 105° C |
| SOLUBILITY IN WATER |
: MISCIBLE |
| SPECIFIC GRAVITY, (WATER=1) | :1.03 @ 25 DEGREE C |
| VAPOR PRESSURE |
: 20.1mmHg @ 25 DEGREE C |
| VAPOR DENSITY, (AIR=1): | : .62 @ 25 DEGREE C |
| pH |
: UNREADABLE, GENERALLY 3 |
| EVAPORATION RATE, (WATER=1): | :SLOW |
Remarks / Precautions
LIME Marine does not corrode, erode, attack, oxidize or have other deleterious affects on virtually any metal or materials found in marine water systems such as: BRASS, IRON, LEATHER, CERAMIC ,WOOD, FIBER, PLASTICS FIBERGLASS, COPPER, STEEL, TITANIUM ,COPPER NICKEL ,RUBBER, GLASS, GELCOATS PAINTED SURFACES.
LIME Marine is an electrolyte, as are most cleaning agents. An electrolyte is any liquid that will transfer small electrical currents. Examples: salt water, vinegar, Coca-Cola. An electrolyte may cause plating in some types of equipment. This means a transfer of small amounts of one metal onto another metal according to the galvanic corrosion chart. In some instances, a thin coating of copper may be plated onto a steel drum while circulating an electrolyte such as RXLYME Marine. The only time plating occurs is when two dissimilar metals are in an electrolyte solution.
It is recommended, but not mandatory, that the LIME Marine solution be thoroughly mixed before using. Some settling of a dark precipitate may occur, resulting in an amber colored liquid, but has no negative affects upon the performance of the solution.
Industries & Applications
-
Marine and shipping industry
-
Ship repair and dry-docking
-
Offshore support vessels
-
Marine engine cooling systems
-
Seawater cooling installations
-
Industrial heat exchangers
-
Power generation facilities
-
Desalination plants
-
Industrial water treatment
-
Mechanical maintenance contractors
Notes
Types of Deposits Removed
|
Deposit Type |
Expected Cleaning Action |
|---|---|
|
Calcium Carbonate Scale |
Dissolution with a suitable descaling formulation |
|
Magnesium Carbonate Deposits |
Chemical dissolution |
|
Hard Water Scale |
Removal of common carbonate-based deposits |
|
Seawater Mineral Encrustation |
Loosening and dissolution of susceptible mineral deposits |
|
Mineral Fouling in Heat Exchangers |
Helps restore clean heat-transfer surfaces |
|
Salt Deposits |
Removal where soluble or chemically susceptible |
|
Calcium Sulphate Scale |
Effectiveness depends on formulation and deposit structure |
|
Silica-Based Scale |
May require a specialized cleaning chemistry |
Note: Not all mineral scales respond equally to the same descaling chemical. Silica-rich, sulphate-rich and mixed biological/mineral deposits may require different treatment methods.
Advantage :
- The solution does not deteriorate, oxidize, saponify, thicken or lose effectiveness for at least five years.
- The solution is of a pleasant or characteristic odor, very similar to cherries, and does not exude any obnoxious or toxic vapors. In rare instances, problematic vapors may occur when encountering high concentrations of sulfur or chlorine. Please contact the manufacturer before proceeding under these circumstances.
- The solution does not require neutralizers and it is free rinsing with water.
- The solution has the ability to dissolve deposits from some equipment while in operation and without shutdown, if auxiliary coolers are incorporated.
- The solution has the properties to be mailed or shipped by any private or commercial carrier without restrictions. Air carriers for emergency deliveries may ship LIME Marine via next day air.
- No Need circulate material for more than a four-hour period without consulting the manufacturer. Most LIME Marine cleaning applications can be accomplished within an average of two to four hours.Please use material only as directed.
This allows the solution to be water flushed down normal plant sewers. Check with local ordinances and regulations in your area prior to disposal.
Our company is holding no-1 RXSOL Brand Descaling Boilers Chemical as a Descaling Chemicals Manufacturers, Descaling Chemicals Wholesale Suppliers, Descaling Chemical suppliers, dealers, distributors India and Descaling Chemical exporters for UAE.
We have supply network in Rabale, Navi Mumbai, Mumbai, Surat, Kandla, Gandhidham, Mundra, Sikka, Chennai, Ennore, Vizag, Visakhapatnam, Kakinada, Kolkata, haldia, Paradip, Fujairah, Dubai, Middle East
Packing Sizes
Material Safety Data Sheet (MSDS)

| Product Name |
LIME Marine ( Marine Water Scale Remover) |
| Product Type | RXSOL-16-1747-025 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Kolkata, Visakhapatnam, Chennai, Hazira, Fujairah, Muscat, Nairobi
| Phone | +91 22 65113333/ 5555 / 9999 / 27611360 / 27815540 |
| Fax | +91 22 2781 1318 :::AOH :0091 9322594669 |
| mail@rxmarine.com |

MATERIAL OR COMPONENT TLV (p.p.m.) PEL (p.p.m.) APPROXIMATE %
HYDROGEN CHLORIDE, AQUEOUS 5 5 LESS THAN 10
Inhibitor Proprietory Blend ... ... More then 40

|
Threshold Limit Value: |
:None For Total-Material Is An Aqueous Organic Salt Solution And As Such Has Little Vapor Pressure And No Noxious Fumes. |
|
Effects Of Overexposure |
:Should Not Be Considered Hazardous When Used As Directed. |
|
Emergency & First Aid |
:If Eye/Skin Contact, Copious Water Rinse. Consult Physician. Not To Be Taken Internally. If Ingested-Do Not Induce Vomiting-Drink Milk, Egg Whites, Etc. As Directed By Physician. |
|
Note: Adverse Effects On Human Health Are Not Expected From The Lime Marine Solution. |
|
Contact with skin: Remove contaminated clothing immediately and drench affected skin with plenty of
water. Then wash with soap and water When in doubt or symptoms persist, seek
medical attention. Contaminated clothing should be laundered before reuse.
Contact with eyes : If substance has got into eyes, immediately wash out with plenty of water for at least 15
minutes. Irrigate eyes thoroughly whilst lifting eyelids Seek. immediate medical attention.
Continue flushing with water until medical help arrives.
Ingestion: Never make an unconscious person vomit or drink fluids Give plenty of water to drink Do not
induce vomiting Seek immediate medical attention.
Inhalation: Remove patient to fresh air Keep warm and at rest, in a half upright position. Loosen clothing.
When in doubt or symptoms persist, seek medical attention.
General: In case of accident or if you feel unwell, seek medical advice immediately (show the label where
possible) (S45).
FLASH Point: No Flash Point, Extinquishes Flame
Extinquishing Media: Does Not Support Combustion
Special Fire Fighting Procedures: None–Water Will Control, Or Co2/Dry Chemicals
Unusual Fire & Explsion Hazards: Non-Combustible Or Explosive. Breathing Apparaus Recommended

Personal Precautions: Wear protective clothing as per section 8 Vapours are heavier than air and may
travel considerable distances to a source of ignition and flashback.
Environmental Precautions: Do not allow to enter public sewers and watercourses.
Immediate Actions: Use appropriate containment to avoid environmental contamination (S57).
Clean Up Actions: Absorb spillage in inert material and shovel up Ventilate the area and wash spill site
after material pick-up is complete.
Special Precautions: Wear protective clothing as per section 8 Avoid release to the environment. Refer to
special instructions/Safety data sheets (S61) Vapours are heavier than air and may
travel considerable distances to a source of ignition and flashback.

Ventilation: 1. Local Exhaust: Normal
2. Mechanical: Sufficient
3. Respiratory: None
Protective Gloves: Recommended, Such As Neoprene Gloves.
Eye Protection: Recommended, Such As Chemical Goggles.
Other Protective Equipment: As Recommended By Plant Safety Department. To
revent Staining Of Clothes, Wear An Apron.

Action To Take For Spills: Rinse With Copious Amounts Of Water To Dilute: Sodium
Bicarbonate May Also Be Used To Soak Up And Neutralize Liquid.
Disposal Method: Expended Or Used Material May Be Disposed Of Down Sewer
With Water Flush. Material Is Biodegradable-Even As Received

|
Boiling Point: ° C. |
105 |
|
Solubility In Water: |
Miscible |
|
Specific Gravity, (Water=1): |
1.03 @ 25 Degreec |
|
Vapor Pressure: |
20.1mmhg @ 25 Degree C |
|
Vapor Density, (Air=1): |
.62 @ 25 Degree C |
|
Percent Volatile By Volume: |
~99.0% |
|
Appearance: |
Dark Liquid |
|
Odor: |
Roasted Almonds |
|
Ph: |
Unreadable, Generally 3 |
|
Evaporation Rate, (Water=1): |
Slow |
|
Physical State: |
Liquid |

- This article is considered stable under normal conditions, May cause rubber to swell
- Avoid overheating
- Incompatible with strong oxidizing substances, Contact with alkaline earth metals may form explosive
gases, Contact with alkali metals may form explosive gases
- See Section 5

Contact with skin: In cases of severe exposure, redness and irritation may develop
Contact with eyes: Causes severe irritation
Ingestion: May cause gastro-intestinal disturbances
Carcinogenicity: No evidence of carcinogenic effects

Handling And Storing: Preserve Integrity Of Container.
Can Material Be Stored Outside? Yes, Maintain Temperature Between 10°-180° F.
Is Material Freezable? Yes. 0º F

Classification: This material and/or its container must be disposed of as hazardous waste EU Waste class
Disposal considerations Do not discharge into drains or the environment, dispose to
anauthorised waste collection point Disposal should be in accordance with local, state or
national legislation.

Not classified as a hazardous for transport

Stability: Table
Incompatibilities: Trong Caustics
Hazardous Decomposition Products: None
Hazardous Polymerization: Will Not Occur
Conditions To Avoid: Excessive Heating

Text of R and S phrase codes used in this safety data sheet:-
R34 Causes burns;
R36 Irritating to eyes;
R37 Irritating to respiratory system;
R41 Risk of serious damage to eyes.
The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use for other appli-cation(s) without seeking advice from manufacturer.
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.
Supply Locations
LIME Marine manufacturer and supplier in Mumbai, Kandla, Vizag - Visakhapatnam, Chennai - Ennore, Kolkata - Haldia - Paradip, Fujairah - Dubai, Abu Dhabi - Sharjah, Muscat Barka RUWI, Oman Sohar, Nairobi Kenya Uganda Africa
Need pricing or a bulk quote?
Send us the product and quantity — our team replies with a quote same day.

