Product code  RXSOL-11-8865-025

High Performance Scale Remover for HVAC Chillers, Heat Exchangers, Condensers and Cooling Water Systems

Same-day UAE delivery Bulk & custom packaging Technical support included

Product Description

RXSOL TECHNICAL PRODUCT BULLETIN

HVAC CHILLER DESCALING CHEMICAL

 

High Performance Scale Remover for HVAC Chillers, Heat Exchangers, Condensers and Cooling Water Systems

Brand: RXSOL Product Category: HVAC Maintenance Chemicals / Industrial Descaling Chemicals Product Type: Inhibited Acid-Based Descaling Chemical (Proposed Formulation) Application: Chiller Condensers, Heat Exchangers, Cooling Towers and Industrial Water Circuits

Product Description

 
RXSOL HVAC Chiller Descaling Chemical is a specialized industrial cleaning chemical intended for the removal of hard water scale, calcium carbonate deposits, magnesium-based deposits and other susceptible mineral encrustations from compatible HVAC chiller systems.
 
During continuous operation, condenser tubes, heat exchangers and cooling water circuits can accumulate mineral deposits due to dissolved salts present in circulating water. These deposits form an insulating layer on heat-transfer surfaces, reducing cooling efficiency and increasing operating pressure and energy consumption.
 
RXSOL HVAC Chiller Descaling Chemical is intended to dissolve mineral scale through controlled chemical circulation, helping restore heat-transfer performance and improve water flow.
 
The product is suitable for selected water-cooled chiller condensers, shell-and-tube heat exchangers, cooling tower piping and industrial cooling equipment, subject to material compatibility and equipment manufacturer approval.
RXSOL HVAC Chiller Descaling Chemical is a specialized industrial cleaning chemical intended for the removal of hard water scale, calcium carbonate deposits, magnesium-based deposits and other susceptible mineral encrustations from compatible HVAC chiller systems.
 
During continuous operation, condenser tubes, heat exchangers and cooling water circuits can accumulate mineral deposits due to dissolved salts present in circulating water. These deposits form an insulating layer on heat-transfer surfaces, reducing cooling efficiency and increasing operating pressure and energy consumption.
 
RXSOL HVAC Chiller Descaling Chemical is intended to dissolve mineral scale through controlled chemical circulation, helping restore heat-transfer performance and improve water flow.
 
The product is suitable for selected water-cooled chiller condensers, shell-and-tube heat exchangers, cooling tower piping and industrial cooling equipment, subject to material compatibility and equipment manufacturer approval.
 

Descaling Chemical Compound for Chiller & Condenser Tubes of Central AC Plants

Descaling chemical compounds for chillers and condenser tubes are specialized cleaning chemicals used to remove scale, mineral deposits, rust, corrosion products, and waterborne deposits from HVAC and central air-conditioning systems.

In central AC plants, hard-water deposits can accumulate on the internal surfaces of chiller heat exchangers, condenser tubes, cooling-water circuits, and associated equipment. If these deposits are not controlled, they can reduce heat-transfer efficiency, increase energy consumption, restrict water flow, and negatively affect overall chiller performance.

A properly selected chiller descaling chemical helps dissolve and remove these deposits while supporting efficient heat transfer and restoring system performance.

Descaling Chemical  Compound Suitable for Descaling of Copper tube of Chillers and Condenser of Air Conditioning Plant. Advanced formulation and Non Corrosive to material Non Polluting and Effective to remove Scale deposited inside Copper tubes. This Compound is Safe to handle also.

Application & Usage

What Causes Scale in Chiller & Condenser Tubes?

Central AC plants often operate with continuous water circulation. Depending on water chemistry, minerals such as calcium carbonate, calcium sulfate, magnesium deposits, silica, iron oxides, and other contaminants can accumulate on heat-transfer surfaces.

The problem can become more severe when:

  • Hard water is used

  • Cooling-water treatment is inadequate

  • Water circulation is poor

  • Blowdown is insufficient

  • pH and alkalinity are not properly controlled

  • Equipment operates continuously for long periods

The resulting deposits form an insulating layer over heat-transfer surfaces.

RXSOL-41-8865-025 contains a powerful dissolving agent for various mineral compounds. Early stage uses of  RXSOL-41-8865-025 prohibit scales build up which results in tube blockage, or regular cleaning is recommended as well. It is impossible to do a circulating cleaning when the tube is completely blocked.

* Calcium sulfate is easier to be formed when the temperature goes higher.

Dosage

The most effective method of RXSOL-41-8865-025 is circulation for large systems or components. In the case of small components, the soak method in an immersion bath can be used.

If the equipment to be cleaned is contaminated by oil, grease, sludge or carbonised oil, then pre-cleaning with RXSOL-20-2002-SC or Rxsol-10-1006 is necessary.
 

Why Chiller Descaling is Important

Scale acts as a thermal barrier between the circulating water and the metal surface. Even a relatively thin deposit can reduce heat-transfer efficiency.

Regular inspection and appropriate chemical cleaning can help:

  • Restore heat-transfer efficiency

  • Improve condenser performance

  • Reduce energy consumption

  • Improve chilled-water system operation

  • Remove mineral deposits

  • Improve water circulation

  • Reduce maintenance problems

  • Extend equipment service life

Useful Area

Specially formulated compound for removing stubborn scale and deposits from chiller condenser tubes. Helps restore smooth water flow and improve cooling efficiency. Suitable for central AC plants in commercial and industrial systems. Acts fast on mineral build-up and hard water scaling. Easy to circulate through existing cleaning systems.

  • Quickly removes scale and deposits
  • Improves cooling performance
  • Supports longer equipment life
  • Suitable for regular maintenance cleaning
  • Easy to apply through circulation method

Industrial Area

Proposed Technical Properties

Property

Proposed Specification

Product Name

HVAC Chiller Descaling Chemical

Brand

RXSOL

Appearance

Clear to slightly coloured liquid

Chemical Nature

Inhibited acid-based descaling formulation

Primary Function

Dissolution of mineral scale

Target Deposits

Calcium carbonate and other acid-soluble deposits

pH

Acidic; formulation-dependent

Specific Gravity

To be confirmed by finished-product testing

Solubility

Water-dilutable, subject to formulation

Cleaning Method

Controlled circulation / immersion

Corrosion Inhibitor

Suitable inhibitor required for selected metallurgy

Working Temperature

To be established by compatibility testing

Packing

25 L cans / drums / IBC, subject to availability

These are proposed formulation characteristics, not verified batch specifications.

RXSOL Product Identification

RXSOL already lists a dedicated chiller descaling product:

Particular

Details

Product Name

Descaling Chemical Compound for Chiller & Condenser Tubes

RXSOL Product Code

RXSOL-41-8865-025

Appearance

Viscous liquid

pH (Neat)

Below 2.0

Specific Gravity

1.20 ± 0.05

Water Solubility

Completely soluble

Primary Application

Chiller and condenser tube descaling

Packing

25 L

These are published catalogue specifications, not independently verified batch results.

THINK RXMARINE
+1

 

Product Page: RXSOL Chiller Descaling Chemical

Recommended Chemical Cleaning Procedure

  1. Inspect the equipment. Identify the scale composition and confirm whether the tubes are copper, copper-nickel, stainless steel, aluminium brass or another material.

  2. Isolate the affected circuit. Shut down the chiller, isolate the water circuit and connect suitable chemical-resistant circulation equipment.

  3. Pre-flush with clean water. Remove loose debris and sludge. If oil or grease is present, carry out a compatible degreasing stage first.

  4. Prepare the descaling solution. Add the product to water at the concentration specified in the approved product TDS. Never assume a universal dilution ratio.

  5. Circulate the solution. Maintain appropriate flow and monitor temperature, pH, scale dissolution and signs of metal attack.

  6. Check cleaning progress. Monitor the solution and inspect representative surfaces. pH alone is not sufficient to establish cleaning completion.

  7. Drain and rinse. Collect the spent descaling solution, flush thoroughly and perform controlled neutralization where required.

  8. Restore water treatment. Apply the appropriate corrosion inhibitor and reinstate the approved cooling water treatment programme before returning to service.

 

 

Recommended Concentration and Contact Time

For RXSOL-41-8865-025, the concentration and contact time must be selected according to deposit thickness, equipment metallurgy, water volume and the manufacturer's approved procedure.

The published product literature mentions extended circulation for difficult deposits, but these conditions should not be treated as universal instructions.

Marine Chemicals

 

A qualified cleaning contractor should establish:

  • Descaling chemical concentration

  • Maximum operating temperature

  • Circulation flow rate

  • Maximum contact time

  • Corrosion monitoring requirements

  • Final rinse and neutralization criteria

Post-Descaling Neutralization and Passivation

After chemical cleaning, the equipment should be rinsed thoroughly to remove residual acidity and dissolved contaminants.

For carbon steel systems, a compatible corrosion inhibitor or passivation treatment may be required to prevent flash rusting.

For copper and copper-alloy condensers, post-cleaning treatment should be selected specifically for the metallurgy. A steel passivator should not automatically be used on copper tubes.

The final rinse water should meet the equipment manufacturer's cleanliness and water chemistry requirements before the system is returned to operation.

Safety and Handling

  • Wear chemical-resistant gloves, protective clothing and suitable eye/face protection.

  • Use acid-compatible pumps, hoses and containers.

  • Never mix the descaler with hypochlorite, chlorine products or incompatible cleaners.

  • Provide adequate ventilation.

  • Allow for gas evolution during carbonate scale dissolution.

  • Never operate a reacting acid-cleaning system as a sealed, unvented circuit.

  • Avoid prolonged contact with sensitive metals.

  • Collect and dispose of spent cleaning solutions according to local regulations.

RXSOL HVAC Chiller Descaling Chemical Supplier – India, UAE & Oman

RXSOL CHEMO PHARMA INTERNATIONAL supplies industrial cleaning and water treatment chemical products through its regional networks.

Country

Supply Locations

Website

India

Mumbai, Navi Mumbai, Surat, Kandla, Mundra, Chennai, Kolkata, Visakhapatnam

RXSOL India

UAE

Dubai, Fujairah, Sharjah, Abu Dhabi

DUBI CHEM UAE

Oman

Muscat, Sohar, Salalah, Duqm

Oman Chemical

Product availability and delivery arrangements should be confirmed for the requested location.

Frequently Asked Questions

Q1. Which RXSOL chemical is suitable for HVAC chiller descaling?

RXSOL-41-8865-025 is a published RXSOL product intended for descaling chiller and condenser tubes.

Q2. Can it remove calcium carbonate deposits?

Yes. Calcium carbonate is a principal target for suitable acid-based descaling formulations.

Q3. Is it safe for copper condenser tubes?

It is marketed for copper condenser tube descaling, but safe use depends on the actual formulation, corrosion inhibitor, dilution, temperature and contact time.

Q4. Can it be used in plate heat exchangers?

Potentially, after verifying compatibility with the plate material and gaskets.

Q5. Does chiller descaling improve cooling performance?

Removing scale can restore lost heat-transfer performance and improve water flow where mineral fouling is responsible for reduced efficiency.

 

HVAC Chiller Descaling Chemical Manufacturer & Supplier India UAE Oman | RXSOL

RXSOL HVAC Chiller Descaling Chemical RXSOL-41-8865-025 for condenser tubes, heat exchangers and cooling water systems. Descaler supplier in Mumbai, Chennai, Dubai, Fujairah, Abu Dhabi and Muscat.

hvac-chiller-descaling-chemical-rxsol

HVAC Chiller Descaling Chemical, RXSOL Chiller Descaler, Chiller Condenser Tube Cleaning Chemical, Heat Exchanger Descaling Chemical, Chiller Descaling Chemical Supplier Dubai, HVAC Descaler India, Chiller Descaling Chemical Oman, RXSOL-41-8865-025.

Image Alt Text: RXSOL HVAC Chiller Descaling Chemical for removal of calcium carbonate scale from condenser tubes and industrial heat exchangers.

 

#Chiller_Descalant
#ChillerDescalant_manufacturerSUPPLIER
#ChillerDescalant_MuscatDUBAI

Technical Specifications

Descaling Chemical compound Should have following Properties

Odour

Characteristic smell

Appearance

Viscous Liquid, soluble in water

pH (Neat)   

  2.0 at 100 % concentration

Boiling point

~ 100 °C at 760 mm /Hg

Vapour pressure

105.5 at 20 deg C

Specific gravity (water=1)

1.20±0.05

Freezing point~

30 °C at 760 mm/Hg

Solubility with water at 20 degree C

    100%

Flammable Non combustible 

Remarks / Precautions

RXSOL- 41-8865-025 should alway be used in plastic bucket. RXSOL-41-8865-025 should always be added in , never add water in RXSOL-41-8865-025.
 

Chiller Descaler with Corrosion Inhibitor

A professional-grade chiller descaling chemical may contain corrosion inhibitors to help minimize attack on compatible metal surfaces during the cleaning process.

However, corrosion-inhibited does not mean universally safe for every metal. Compatibility testing is particularly important where systems contain copper, brass, galvanized steel, aluminum, stainless steel, rubber components, coatings, or mixed metallurgy.

Descaling Chemical for Condenser Tubes – Supplier

When selecting a descaling chemical supplier for chiller and condenser tubes, customers should look for a supplier that can provide technical guidance according to the type of equipment and deposit.

Important documentation includes:

  • Technical Data Sheet (TDS)

  • Safety Data Sheet (SDS)

  • Recommended dilution ratio

  • Application procedure

  • Material compatibility information

  • Storage and handling instructions

  • Certificate of Analysis (COA), where applicable

Preventing Scale After Descaling

Chemical cleaning removes existing deposits, but proper water treatment is important to prevent rapid scale redevelopment.

A comprehensive central AC water-treatment program may include:

  • Scale inhibitor

  • Corrosion inhibitor

  • Biocide

  • pH control

  • Water-quality monitoring

  • Proper blowdown

  • Periodic condenser inspection

  • Regular cleaning and maintenance

Combining preventive water treatment with periodic descaling can help maintain long-term chiller and condenser performance.

Safety Precautions

Descaling chemicals may contain acidic or otherwise reactive ingredients. They should be handled only by trained personnel using appropriate gloves, goggles/face protection, protective clothing, and other PPE specified in the SDS.

Never mix different cleaning chemicals unless compatibility has been confirmed by the manufacturer. Ensure adequate ventilation and follow applicable procedures for chemical disposal and wastewater discharge.

Conclusion

Descaling Chemical Compound for Chillers and Condenser Tubes of Central AC Plants is an important maintenance solution for removing mineral scale and deposits that reduce heat-transfer efficiency.

Regular inspection, appropriate chemical descaling, and preventive cooling-water treatment can help maintain efficient heat transfer, stable chiller operation, improved condenser performance, and longer equipment service life.

For central AC plants, commercial HVAC systems, hospitals, hotels, malls, industrial facilities, and other large cooling installations, the correct descaling chemical should always be selected according to the deposit type, equipment metallurgy, system design, and manufacturer's cleaning recommendations.

Notes

Applications of Descaling Chemical

A suitable descaling chemical compound can be used for cleaning various components of central AC and HVAC systems, subject to material compatibility.

1. Chiller Heat Exchangers

Chemical descaling can help remove mineral deposits from heat-transfer surfaces inside compatible chiller heat exchangers.

2. Condenser Tubes

Condenser tube descaling is one of the most important applications. Deposits inside condenser tubes can restrict water flow and reduce heat transfer between the refrigerant system and cooling water.

3. Central AC Plants

Large central air-conditioning systems can develop scale and deposits in cooling-water circuits over time. Periodic chemical cleaning can help maintain system efficiency.

4. Cooling Water Circuits

Descaling chemicals may also be used in selected cooling-water equipment, heat exchangers, pipelines, and associated components.

How Does Chiller Descaling Chemical Work?

Most descaling formulations use an acidic or specialty chelating chemistry capable of dissolving mineral deposits. The chemical reacts with deposits such as carbonate scale and converts them into soluble compounds that can be removed during circulation and flushing.

The choice of chemistry depends on:

  • Type of scale

  • Thickness of deposits

  • Equipment metallurgy

  • Presence of copper, brass, steel, stainless steel, or other materials

  • System temperature

  • Cleaning time

  • Required cleaning strength

  • Environmental and discharge requirements

For this reason, the strongest acid is not necessarily the best descaling chemical. A properly formulated product should balance deposit removal with material compatibility and corrosion control.

Descaling Condenser Tubes in Central AC Plants

A typical chemical-cleaning procedure involves isolating the equipment, circulating the appropriate diluted descaling solution through the affected circuit, monitoring the cleaning process, and subsequently flushing the system thoroughly with clean water.

Before chemical cleaning:

  1. Identify the type of scale.

  2. Confirm the metallurgy of the condenser/chiller.

  3. Isolate the equipment safely.

  4. Inspect the system and establish the required cleaning method.

  5. Prepare the descaling solution according to the manufacturer's instructions.

  6. Circulate the solution for the recommended period.

  7. Monitor pH and cleaning progress where appropriate.

  8. Drain the spent solution safely.

  9. Thoroughly rinse and neutralize the system as required.

  10. Return the equipment to service after confirming acceptable conditions.

Dosage, concentration, circulation time, and neutralization requirements should always be based on the specific chemical manufacturer's technical instructions.

Advantages of a Quality Chiller Descaler

A properly formulated descaling compound can offer:

  • Effective removal of carbonate scale

  • Removal of mineral deposits

  • Improved heat transfer

  • Better condenser efficiency

  • Improved water flow

  • Reduced maintenance requirements

  • Faster cleaning compared with mechanical methods in suitable applications

  • Corrosion-inhibited cleaning when the formulation is designed for the equipment

  • Application flexibility for HVAC and industrial heat exchangers

Descaling Chemical Compound for Chiller, Condenser tube of Central AC Plant manufacturer and supplier in INDIA and Middle East. We have stock point in Navi Mumbai - Turbha, Mumbai, JNPT, Surat, Gandhidham, Mundra, Kandla, Chennai, Ennore, Vizag, Visakhapatnam, Kakinada, Kolkata, Haldia, PAradip, Manglore, Goa. And in GULF we have supply range for Fujairah, Dubai, Sharjah, Abu Dhabi, Saudi, Kuwait.

Our name is very popular for producer and exporter of Descaling Chemical Compound for Chiller, Condenser tube of Central AC Plant .

Packing Sizes

Descaler for Chiller plant available in Dubai, Muscat, Mumbai, Kolkata, Chennai, Vizag, Surat, Gnadhidham in 5, 20, 25, 60 Heavy duty HMHDPE carboy. Factory sale for our regular customer on heavy discounted scheme available.

Material Safety Data Sheet (MSDS)

Product Name RXSOL-41-8865-025
Product Type Descaling Chemical Compound for Chiller, Condenser tube of Central AC Plant

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Phone +91 22 65113333 / 5555 / 9999 / 27611360
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email 123@rxmarine.com
Website www.rxmarine.com

Chemical Name

Concentration

CAS Number

EC Number

R Phrases*

Symbols

 Polymer Chlorous Acid

20-40

Proprietiry

 NA   

34, 37

C

Corrosion Inhibitor

 5-10

NA 

 NA

NA 

 

Phosphoric Acid 10-30 7664-38-2 NA 34 C
proprietary Blend of Polymer ( For protection of Pitting on metal surface ) 20-30 ------------ ------------ --------- -------

*See Section 16

Odour

Characteristic Smell

Appearance

Clear Liquid, soluble in water

Contact with eyes

Can cause damage to the eyes

Contact with skin

Prolonged skin or eye contact may cause chemical burns

Inhalation

Causes  severe  irritation,  May  cause  breathing  difficulty

Ingestion

Not regarded as a potential route of exposure.,Causes burning sensation  


Contact with skin

Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash with soap and water When in doubt or symptoms persist, seek medical attention. Contaminated clothing should be laundered before reuse 

Contact with eyes
 

If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes. Irrigate eyes thoroughly whilst lifting eyelids Seek. immediate medical attention. Continue flushing with water until medical help arrives. 

Ingestion

Never make an unconscious person vomit or drink fluids Give plenty of water to drink Do not induce vomiting Seek immediate medical attention 

Inhalation

Remove patient to fresh air Keep warm and at rest, in a half upright position. Loosen clothing. When in doubt or symptoms persist, seek medical attention.

General

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45).

-  Non combustible.
-  Smoke from fires is corrosive, Hydrogen chloride may be formed.
-  Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions.
-  Substance evolves toxic fumes, wear self-contained breathing apparatus.
-  Use water spray or fog to knock down and absorb corrosive fumes.

Personal Precautions

Wear protective clothing as per section 8 Vapours are heavier than air and may travel considerable distances to a source of ignition and flashback. 

Environmental Precautions

Do not allow to enter public sewers and watercourses.

Immediate Actions

Use appropriate containment to avoid environmental contamination (S57).

Clean Up Actions

Absorb spillage in inert material and shovel up Ventilate the area and wash spill site after material pick-up is complete. 

Special Precautions

Wear protective clothing as per section 8 Avoid release to the environment. Refer to special instructions/Safety data sheets (S61) Vapours are heavier than air and may travel considerable distances to a source of ignition and flashback.

Handling

Avoid contact with skin and eyes (S24/25).Do not breathe vapour/fumes (S23).Eyewash bottles should be available.Wear protective clothing as per section 8.Ensure adequate ventilation.In use, may form flammable/explosive vapour-air mixture (R18).

Storage

Keep only in the original container in a cool, well ventilated place (S3/9/49). Keep in acid store.

Exposure Limits

TLV (TWA) 20 ppm, 122 mg/m3 (1,2-Dichlorobenzene).

Exposure controls

The undiluted product must not be used in a confined space without good ventilation.

Occupational exposure  controls

Wear approved respirator if exposure likely to exceed MEL/OES  Wear goggles giving complete eye protection Wear suitable protective clothing, including eye/face protection and gloves (neoprene or nitrile  are recommended).

 

 

Odour

Characteristic smell

Appearance

Clear Liquid, soluble in water

PH

1.5 at 100 % concentration

Boiling point

~ 100 °C at 760 mm /Hg

Vapour pressure

105.5 at 20 deg C

Vapour density (air = 1)

1.26

Freezing point~

30 °C at 760 mm/Hg

Completely soluble in water

Specific gravity (water=1)

1.16

Non combustible 

-  This article is considered stable under normal conditions, May cause rubber to swell
-  Avoid overheating
-  Incompatible with strong oxidizing substances, Contact with alkaline earth metals may form explosive gases, Contact with alkali metals may form explosive gases
-  See Section 5

Contact with skin

In cases of severe exposure, redness and irritation may develop 

Contact with eyes

Causes irritation

Ingestion

May cause gastro-intestinal disturbances

Carcinogenicity

No evidence of carcinogenic effects

Ecotoxicity

This product does not contain ingredients which are classified in the EU as dangerous for theenvironment. 

Mobility

Completely soluble in water .

Persistence and Biodegradability

Its main ingredients will either dissolve rapidly and dissociate in water or are readily/inherently  biodegradable.

Bioaccumulation Potential

Bioaccumulation of the components in this product is insignificant. Other Adverse Effects No environmental problems are expected when the product is used / handled correctly. 

Classification 
 

This material and/or its container must be disposed of as hazardous waste EU Waste class Disposal considerations Do not discharge into drains or the environment, dispose to anauthorised waste collection point Disposal should be in accordance with local, state or national legislation.

Proper Shipping Name:
UN        
  Proper Shipping Name: Solution of Phosphoric ang Hydrozen Chlorde    
  UN NO.

1789

   
  Hazard Class 8 PackingGroup II

Road/Rail(ADR/RID)

  Proper Shipping Name
Solution of Phosphoric ang Hydrozen Chloride
   
  ADR UN No.

1789

   
 

ADRHazardClass

8 Tremcard

80GC1789-II

Sear (IMDG)
  Proper Shipping Name
Solution of Phosphoric ang Hydrozen Chloride
   
  IMDG UN No.

1789

   
  IMDG Hazard Class 8 IMDG PackGroup.:

II

  IMDG EmS F-A, S-B IMDG subrisk

N/A

 

IMDG Labels

8

IMDG Flashpoint:

 N/A

Air(ICAO/IATA)

  ProperShippingName
Solution of Phosphoric ang Hydrozen Chloride
   
  IMDG UNNo

1789

   
  IMDG HazardClass 8 ICAO PackingGroup

II

  ICAO subrisk N/A ICAO Labels:

8+CAO

  ICAO Flashpoint

N/A

   

DOT/ CFR(USDepartment ofTransportation

 

DOTProperShippingName

Solution of Phosphoric ang Hydrozen Chloride
   
 

HazardousMaterial

Solution of Phosphoric ang Hydrozen Chloride
   
  HazardClass 8 IdentificationNumber: UN1789
 

Product RQ (lbs)

N/E DOTsubrisk:

N/A

 

DOTLabels

8

DOTFlashpoint: N/A

- Not classified as hazardous for transport

Risk Phrases

Irritating to eyes (R36) 

Safety Phrases Irritant

In case of contact with eyes, rinse immediately with plenty of water and seek medical advice (S26)Wear suitable gloves and eye/face protection (S37/39) 

Text of R and S phrase codes used in this safety data sheet:-
R34 Causes burns;
R36 Irritating to eyes;
R37 Irritating to respiratory system;
R41 Risk of serious damage to eyes.
The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use for other appli-cation(s) without seeking advice from manufacturer.

Supply Locations

Descaling Chemical Compound for Chiller, Condenser tube of Central AC Plant available in Chennai - Ennore, Mumbai, Visakhapatnam- Gangavaram, Kolkata - Haldia, Kandla - Gandhidham, Fujairah - Dubai

Chiller Descaling Chemical, Descaling Chemical for Chiller, Condenser Tube Descaler, Chiller Cleaner Chemical, Central AC Plant Descaling Chemical, AC Plant Descaler, HVAC Descaling Chemical, Condenser Cleaning Chemical, Chiller Condenser Tube Cleaning Chemical, Chemical Descaler for Heat Exchanger, Heat Exchanger Descaling Chemical, Cooling Tower Descaling Chemical, Central Air Conditioning Cleaning Chemical, Chiller Cleaning Chemical Supplier, Condenser Tube Cleaning Chemical Supplier, HVAC Chemical Supplier, Industrial Descaling Chemical, AC Plant Maintenance Chemical, Chiller Scale Remover, Condenser Scale Remover.

Need pricing or a bulk quote?

Send us the product and quantity — our team replies with a quote same day.

WhatsApp Us