Of Marine Chemical Solutions
Of Marine Chemical Solutions
Pickling Inhibitor
25.00Ltr.
Pickling Inhibitor RXSOL 31 A manufacturer, supplier and exporter.
Product Technical bulletin
1.Product Name-Pickling Inhibitor RXSOL 31 A ( Liquid Acid Builder )
Properties
Application
make-up values: | 3 %vol SurTec 025 (2-5 %vol)+ 0.2-1.0 %vol surfactant booster |
temperature: | 60°C (40-80°C) |
application time: | 5 min (1-15 min) |
agitation: | if required:ultrasonic or rack movement |
tank material: | steel with acid-resistant coating |
heating: | required, out of acid-resistant material |
cooling: | not required |
exhaust: | required for worker’s protection |
Maintenance and Analysis Analyse and adjust the concentration of SurTec 025 regularly.
Sample Preparation
Take a sample at a homogeneously mixed position. Let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
SurTec 025 – Analysis by Titration reagents:
0.1 N sodium hydroxide solution indicator: phenolphthalein
procedure: 1. Pipette 10 ml bath sample into a 250 ml Erlenmeyer flask.
2. Dilute to approx. 100 ml with deionised water.
3. Add 3 drops of indicator.
4. Titrate with 0.1 N sodium hydroxide solution from colourless to pink. calculation: consumption in ml · 0.2663 = %vol SurTec 025
Technical Specification
(at 20°C) Appearance Density (g/ml) pH-value (conc.) SurTec 025 liquid, colourless-yellowish 1.030 (1.11-1.15) approx. 1
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock: SurTec 025 75 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product- Xi – Irritant
hazard designation-SurTec 025
water hazard class-WHC 1
———————————————————————————————————————————————-2.Product- SurTec® 026 Liquid Acid Cleaner
Properties
Application
make-up value: 1-4 %vol
temperature: 40-80°C
application time: 0.5-2 min
Technical Specification
at 20°C) | Appearance | Density(g/ml) | pH-value (at 10 g/l) |
SurTec 026 | liquid, yellowish to dark orange, clear | 1.039 (1.02-1.06) | approx. 2.6 |
Maintenance and Analysis
Analyse and adjust the concentration of SurTec 026 regularly.
Sample Preparation
Take a sample at a homogeneously mixed position. Let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
SurTec 026 – Analysis by Titration
reagents:0.1 N sodium hydroxide solution (NaOH solution)
indicator: phenolphthalein
procedure:
calculation: consumption in ml · 0.78 = %vol SurTec 026
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock: SurTec 026 50 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product – SurTec 026
hazard designation – C – Corrosive
water hazard class- WHC 2
————————————————————————————————————————————–
3.Product-Anticorrosion Spray Cleaner
Properties
Application
is used for cleaning and passivating in single- or multi-chamber spray systems.
make-up value: | 1-4 %vol |
temperature: | room temperature up to 80°C |
application time: | 1-10 min |
Technical Specification
at 20°C | Appearance | Density (g/ml) | pH-value(conc.) |
SurTec010 | liquid, yellowish-reddish | 1.055 (1.04-1.07) | approx. 8.5 |
Maintenance and Analysis
Analyse and adjust the concentration of SurTec 010 regularly.
Sample Preparation
Take a sample at a homogeneously mixed position and let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
Analysis by Titration
reagents: |
0.1 N hydrochloric (or sulfuric) acid indicator: methyl orange solution (0.04 %) |
procedure: |
1. Pipette 20 ml bath sample into a 250 ml Erlenmeyer flask. 2. Dilute with approx. 100 ml deionised water. 3. Add 3 drops of indicator. 4. Titrate with 0.1 N acid from yellow to red. |
calculation: | consumption in ml · 0.3 = %vol SurTec 010 |
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock: SurTec 010 25 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
RXSOL | – | WHC 1 |
—————————————————————————————————————————————————
4.Product- SurTec® 011 Anticorrosion Spray Cleaner
Properties
Application
SurTec 011 is used for cleaning and passivation in single- and multi-chamber spray systems.
make-up value: | 2.5 %vol | 1-4 %vol |
temperature: | 60°C | (30-80°C) |
application time: | 1-10 min |
Technical Specification
at 20°C | Appearance | Density(g/ml) | pH-value (at 20 g/l) |
SurTec 011 | liquid, colourless to yellow/orange, clear | 1.062 (1.05-1.07) | approx. 7.9 |
Maintenance and Analysis
Analyse and adjust the concentration of SurTec 011 regularly.
Sample Preparation
Take a sample at a homogeneously mixed position. Let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
SurTec 011 – Analysis by Titration
reagents: |
0.1 N hydrochloric or sulfuric acid indicator: methyl orange solution (0.04 %) |
procedure: |
1. Pipette 20 ml bath sample into a 250 ml Erlenmeyer flask. 2. Dilute to approx. 100 ml with deionised water. 3. Add 3 drops of indicator. 4. Titrate with 0.1 N acid from yellow to red. |
calculation: | consumption in ml · 0.223 = %vol SurTec 011 |
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock: SurTec 011 25 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 011 | WHC 1 |
—————————————————————————————————————————————
5.Product- SurTec® 001 Anticorrosion Spray Cleaner
Properties
Application
SurTec 001 is used for cleaning and passivating in single- and multi-chamber spray application.
make-up value: | 1.0-5.0 %vol |
temperature: | 30-80°C |
application time: | 1-10 min |
Technical Specification
(at 20°C) | Appearance | Density | pH-value (conc.) |
SurTec 001 | liquid, colourless-yellowish | 1.048 (1.04-1.06) | approx. 8.5 |
Maintenance and Analysis
Analyse and adjust the concentration of SurTec 001 regularly.
Sample Preparation
Take a sample at a homogeneously mixed position. Let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
SurTec 001 – Analysis by Titration
reagents: |
0.1 N hydrochloric or sulfuric acid indicator: methyl orange solution (0.04 %) |
procedure: |
1. Pipette 25 ml bath sample into a 250 ml Erlenmeyer flask. 2. Dilute to approx. 100 ml with deionised water. 3. Add 3 drops of indicator. 4. Titrate with 0.1 N acid from yellow to red. |
calculation: | consumption in ml · 0.219 = %vol SurTec 001 |
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock:SurTec 001 50 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product – SurTec 001
hazard designation- None
water hazard class – WHC 1
————————————————————————————————————————————————
6. Product- SurTec® 005 Neutral Spray Cleaner
Properties
Application
SurTec 005 is used for cleaning and passivating of iron parts in single and multi chamber spray application.
make-up value: | 1-3 %vol |
temperature: | 30-80°C |
application time: | 1-10 min |
hint: | Test aluminium and copper alloys before treating with SurTec 005. |
Technical Specification
(at 20°C) | Appearance | Density (g/ml) | pH-value (conc.) |
SurTec 005 | liquid, colourless to yellow/orange, clear | 1.143 (1.13-1.16) | approx. 10 |
Maintenance and Analysis
Analyse and adjust the concentration of SurTec 005 regularly. Dosage of SurTec 005 according to conductivity is possible.
Sample Preparation
Take a sample at a homogeneously mixed position. Let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
SurTec 005 – Analysis by Titration
reagents: |
0.1 N hydrochloric acid indicator: methyl orange solution (0.04 %) |
procedure: |
1. Pipette 20 ml bath sample into a 250 ml Erlenmeyer flask. 2. Dilute to approx. 100 ml with deionised water. 3. Add 3 drops of indicator. 4. Titrate with 0.1 N hydrochloric acid from yellow to red |
calculation: | consumption in ml · 0.266 = %vol SurTec 005 |
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock : SurTec 005 50 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 005 | WHC 1 |
———————————————————————————————————————————————
7. Product- SurTec® 573 Stainless Steel Passivation
Properties
Application
SurTec 573 is used in immersion application.
make-up value: | 24-55 %vol |
temperature: | 21-32°C |
pH-value: | < 1 (50 %solution) |
application time: | ≥ 30 min |
agitation: | to get best passivation results move the bath by air injection |
tank material: | polypropylene (PP) tanks |
heating: |
required, made of acid resistant material; outer tank walls should be insulated to avoid energy loss |
exhaust: | required for worker´s protection |
hints: |
Principally tap water or soft water can be used for bath preparation (chloride content < 10 ppm). Additionally ultrasonic support can increase the cleansing effect of the passivation process. |
Technical Specification
(at 20°C) | Appearance | Density (g/ml) | pH-value (conc.) |
SurTec 573 | fluid, colourless-yellowish clear | 1.33 (1.30-1.36) | < 1 |
Maintenance and Analysis
As by the production constantly bath liquid is dragged out and the active substances will be consumed. So analyse and adjust the concentration of SurTec 573 regularly.
Sample Preparation
Take a sample at a homogeneously mixed position. Let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
SurTec 573 – Analysis by Titration
reagents: |
1 mol/l caustic soda solution (= 1 N NaOH solution) indicator: bromocresol green (0.1 g in 100 ml 20 % ethanol) |
procedure: |
1. Pipette 5 ml bath sample into a 250 ml Erlenmeyer flask. 2. Dilute to approx. 100 ml with deionised water. 3. Add 5-10 drops of indicator solution and mix well (solution becomes yellow). 4. Titrate with 1 mol/l caustic soda solution until the colour changes to blue |
calculation: | consumption in ml · 1.785 = %vol SurTec 573 |
nominal values: |
24-55 %vol SurTec 573 is equivalent to 13.4-30.8 ml of 1 mol/l caustic soda solution |
Ingredients
Consumption and Stock Keeping
The consumption depends heavily on the drag-out. To determine the exact amounts of drag-out, see SurTec Technical Letter 11.
The following values per m2 can be taken as estimated average consumption: SurTec 573 25-75 g
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock: SurTec 573 750 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product – SurTec 573
hazard designation – C – Corrosive
water hazard class – WHC 1
————————————————————————————————————————————————
8.Product- SurTec® 042 Sprayable Immersion Cleaner
Properties
Application
SurTec 042 is applied in immersion-, ultrasonic-, spray- and injection flood wash lines for cleaning and passivation.
make-up value: | 2.5 %vol | (1-4 %vol) |
temperature: | 60°C | (40-80°C) |
application time: | 5 min | (1-10 min) |
Technical Specification
(at 20°C) | Appearance | Density (g/ml) | pH-value (at 10 g/l) |
SurTec 042 | liquid, colourless-yellow | 1.005 (0.99-1.02) | 10.5 (9-12) |
Maintenance and Analysis
Analyse and adjust the concentration of SurTec 042 regularly.
Sample Preparation
Take a sample at a homogeneously mixed position. Let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
SurTec 042 – Analysis by Titration
reagents: 0.1 N hydrochloric or sulfuric acid
indicator: methyl orange solution (0.04 %)
procedure:
1. Pipette 10 ml bath sample into a 250 ml Erlenmeyer flask.
2. Dilute with deionised water to approx. 100 ml.
3. Add 3 drops of indicator.
4. Titrate with 0.1 N acid from yellow to red.
calculation: consumption in ml · 0.4 = %vol SurTec 042
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock ; SurTec 042 25 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product – SurTec 042
hazard designation – C – Corrosive
water hazard class- WHC 2
——————————————————————————————————————————————–
9.Product- SurTec® 051 Emulsion Cleaner
Properties
Application
SurTec 051 is used for cleaning in immersion application lines and for intermediate cleaning with special corrosion protection requirements.
cleaning | rust-proofing | |
make-up values: | 3-10 %vol | 3-25 %vol |
temperature: | room temperature to 70°C |
Technical Specification
(at 15°C) | Appearance | Density (g/ml) | pH-value (at 50 g/l) |
SurTec 051 |
liquid, yellow-orange, clear to slightly turbid |
0.995 (0.98-1.01) | ca. 9.2 (at 20°C) |
Maintenance and Analysis
Analyse and adjust the concentration of SurTec 051 regularly.
Sample Preparation
Take a sample at a homogeneously mixed position. Let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
SurTec 051 – Analysis by Titration
reagents: |
0.1 N hydrochloric or sulfuric acid indicator: methyl orange solution (0.04 %) |
procedure: |
1. Pipette 20 ml bath sample into a 250 ml Erlenmeyer flask. 2. Dilute to approx. 100 ml with deionised water. 3. Add 3 drops of indicator. 4. Titrate with 0.1 N acid from yellow to red. |
calculation: | consumption in ml · 0.448 = %vol SurTec 051 |
Ingredients
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 051 | – | WHC 2 |
——————————————————————————————————————————————–
10. Product- SurTec® 055 Intensive Cleaner
Properties
Application
SurTec 055 can be used manually as well as for high pressure cleaning.make-up value: 2 %vol to undiluted (depending on the degree of contamination)
Technical Specification
(at 20°C) | Appearance | Density (g/ml) | pH-value (at 10 g/l) |
SurTec 055 |
liquid, colourless to pale yellow, clear |
1.010 (1.00-1.02) | approx. 10.6 |
Maintenance and Analysis
Analyse and adjust the concentration of SurTec 055 regularly.
Sample Preparation
Take a sample at a homogeneously mixed position. Let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
SurTec 055 – Analysis by Titration
reagents: |
0.1 N hydrochloric or sulfuric acid indicator: methyl orange solution (0.04 %) |
procedure: |
1. Pipette 10 ml bath sample into a 250 ml Erlenmeyer flask. 2. Dilute to approx. 100 ml with deionised water. 3. Add 3 drops of indicator. 4. Titrate with 0.1 N acid from yellow to red. |
calculation: | consumption in ml · 1.032 = %vol SurTec 055 |
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock: SurTec 055 25 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 055 | Xi – Irritant | WHC 2 |
To neutralise 100 l of a 10 % SurTec 055-solution, 0.8 l of hydrochloric acid (30 %) are needed.
——————————————————————————————————————————————–
11. Product- SurTec® 084 Spray Detergent Booster
Properties
Application
SurTec 084 Spray Detergent Booster is applied as a spray surfactant in combination with builders such as e.g. SurTec 131, SurTec 132, SurTec 138, etc. in single- and multi-chamber installations.
make-up value: | 0.3-1 %vol SurTec 084 + builder |
temperature: | > 30°C |
application time: |
depending on the instructions of the chosen builder |
Technical Specification
(at 20°C) | Appearance | Density (g/ml) |
SurTec 084 | liquid, colourless | 1.024 (1.01-1.04) |
Maintenance and Analysis
Analyse and adjust the concentration of the builder regularly.Replenish SurTec 084 proportional to the dosage of the builder.
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock: SurTec 084 25 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 084 | – | WHC 2 |
————————————————————————————————————————————————-
12Product- SurTec® 085 Recyclable Detergent Component
Properties
Application
make-up value: | 0.3-1 %vol SurTec 085 + builder |
temperature: | > 40°C |
application time: | depending on the instruction of the chosen builder |
Technical Specification
(at 20°C) | Appearance | Density (g/ml) |
SurTec 085 | liquid, colourless-yellowish | 1.005 (0.99-1.02) |
Maintenance and Analysis
Analyse and adjust the concentration of the builder regularly.
Replenish SurTec 085 proportional to the dosage of the builder (e.g. dosing of 3 % builder requires 0.3 %vol tenside booster SurTec 085 Detergent Component).
Ingredients
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 085 | Xi – Irritant | WHC 2 |
——————————————————————————————————————————————-
13. Product- SurTec® 086 Recyclable Spray Surfactant
Properties
Application
make-up value: | 0.3-1 % SurTec 086 + builder |
temperature: | > 40°C |
application time: | depending on the instructions of the chosen builder |
Technical Specification
(at 20°C) | Appearance | Density (g/ml) | pH-value (at 20 g/l) |
SurTec 086 | liquid, colourless-yellowish | 1.003 (0.99-1.01) | 5.7 (5.4-8.6) |
Maintenance and Analysis
Analyse and adjust the concentration of the builder regularly.
Dose SurTec 086 proportional to the dosage of the builder (e.g. dosing of 3 % builder requires 0.3 % tenside booster SurTec 086 Spray Surfactant).
Ingredients
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 086 | – | WHC 2 |
—————————————————————————————————————————————–
14. Product- SurTec® 089 Recyclable Detergent Component
Properties
Application
SurTec 089 is an additive for soak cleaning applications with or without ultra sonic.
make-up value: | 0.3-1 %vol SurTec 089 + builder |
temperature: | depending on the instructions of the chosen builder |
application time: | depending on the instructions of the chosen builder |
Analysis
Add SurTec 089 proportional according to the dosage of the builder (e.g. addition of 3 % builder requires 0.3 % detergent component).
Technical Specification
(at 20°C) | Appearance |
Density (g/ml) |
pH-value (at 2 %vol) |
SurTec 089 | liquid, light yellow to yellow | 1.030 (1.02-1.04) | 9.8 (9.1-10.5) |
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock: SurTec 089 25 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 089 |
Xn – Harmful N – Dangerous for the environment |
WHC 2 |
——————————————————————————————————————————————
15. Product- SurTec® 091 Surfactant Booster
Properties
Application
SurTec 091 Surfactant Booster can be added as tenside component to an alkaline builder (e.g. SurTec 190, SurTec 192) or it can be used as surfactant booster for soak- and ultrasonic cleaning (e.g. SurTec 184, SurTec 188) and for electrolytic degreasing (e.g. SurTec 171, SurTec 199).
make-up values: | 0.1-1 vol% SurTec 091 + builder resp. customized cleaner |
temperature: | depending on the instructions of the chosen builder |
application time: | depending on the instructions of the chosen builder |
Technical Specification
(at 20°C) | Appearance | Density (g/ml) | pH-value (at 20 g/l) |
SurTec 091 | liquid, yellow-orange | 1.070 (1.05-1.09) | approx. 1.5 |
Maintenance and Analysis
Add SurTec 091 proportional according to the analysis and dosage of the builder.
Ingredients
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 091 | C – Corrosive | WHC 2 |
———————————————————————————————————————————————–
16. Product- SurTec® 092 Emulsifying Detergent
Properties
Application
SurTec 092 is an additive for soak- and ultrasonic applications. It is used in combination with alkaline,neutral or acid base cleaners (builders).
make-up value: | 0.2-2 %vol SurTec 092 + base cleaner/builder |
temperature: | according to the instruction of the base cleaner |
application time: | according to the instruction of the base cleaner |
Technical Specification
(at 20°C) | Appearance | Density (g/ml) |
SurTec 092 | liquid, light yellow to brownish, clear | 1.032 (1.027-1.037) |
Maintenance and Analysis
Analyse and adjust the concentration of the base cleaner regularly.Replenish SurTec 092 proportional according to the dosage of the base cleaner.
Ingredients
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 092 | Xn – Harmful | WHC 2 |
———————————————————————————————————————————-
17. Product- SurTec® 101 Sprayable Immersion Cleaner
Properties
Application
SurTec 101 is applied in immersion-, ultrasound-, spray- and injection flood wash lines for cleaning and passivating.
make-up value: | 2.5 %vol | (1-4 %vol) |
temperature: | 60°C | (40-80°C) |
application time: | 5 min | (1-10 min) |
Technical Specification
(at 20°C) | Appearance | Density (g/ml) | pH-value (conc.) |
SurTec 101 | liquid, colourless-yellow | 1.057 (1.05-1.07) | approx. 8.3 |
Maintenance and Analysis
Analyse and adjust the concentration of SurTec 101 regularly.
Sample Preparation
Take a sample at a homogeneously mixed position. Let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
SurTec 101 – Analysis by Titration
reagents: |
0.1 N hydrochloric or sulfuric acid indicator: methyl orange solution (0.04 %) |
procedure: |
1. Pipette 20 ml bath sample into a 250 ml Erlenmeyer flask. 2. Dilute with deionised water to approx. 100 ml. 3. Add 3 drops of indicator. 4. Titrate with 0.1 N acid from yellow to red. |
calculation: | consumption in ml · 0.45 = %vol SurTec 101 |
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock: SurTec 101 25 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 101 | – | WHC 2 |
———————————————————————————————————————————————–
18. Product- SurTec® 102 SFT Sprayable Immersion Cleaner
Properties
Application
SurTec 102 SFT is applied in immersion-, ultrasound-, spray- and injection flood wash lines for cleaning and passivating.
make-up value: | 2.5 %vol | (1-4 %vol) |
temperature: | 60°C | (40-80°C) |
application time: | 5 min | (1-10 min) |
Technical Specification
(at 20°C) | Appearance | Density (g/ml) | pH-value (at 20 g/l) |
SurTec 102 SFT | liquid, colourless-yellow | 1.040 (1.02-1.06) | approx. 9.0 |
Maintenance and Analysis
Analyse and adjust the concentration of SurTec 102 SFT regularly.
Sample Preparation
Take a sample at a homogeneously mixed position. Let it cool down to room temperature. If the sample is turbid, let the turbidity settle down and decant or filter the solution.
SurTec 102 SFT – Analysis by Titration
reagents: | 0.1 N hydrochloric or sulfuric acid indicator: methyl orange solution (0.04 %) |
procedure: |
1. Pipette 20 ml bath sample into a 250 ml Erlenmeyer flask. 2. Dilute to approx. 100 ml with deionised water. 3. Add 3 drops of indicator. 4. Titrate with 0.1 N acid from yellow to red. |
calculation: | consumption in ml · 0.219 = %vol SurTec 102 SFT |
Ingredients
Stock Keeping
In order to prevent delays in the production process, per 1,000 l bath the following amount should be kept in stock: SurTec 102 SFT 25 kg
Product Safety and Ecology
The safety instructions and the instructions for environmental protection have to be followed in order to avoid hazards for people and environment. The Material Safety Data Sheets (according to European legislation) contain explicit details for this.
The following hazard designations and classifications into water hazard classes (WHC) have to be taken into account:
product | hazard designation | water hazard class |
SurTec 102 SFT | – | WHC 2 |
———————————————————————————————————————————————
Product label
Request for Quote and Get Heavy Discount on Price